Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete manual as pdf-file in very good quality. Very helpful and fast availability.
 ;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
 ;
Service manual in good quality, it was very helpful to me. Perfect service, I am very satisfied.
Jochen Kelm
 ;
Exellent manual ,it was in great condition,and got all the info i expected,5 stars!!
PT-LB50NTU / PT-LB50NTE / PT-LB50NTEA / PT-LB50U / PT-LB50E / PT-LB50EA / PT-LB50SU / PT-LB50SE / PT-LB50SEA
7.2.
Removal of Upper Case
1. Turn the projector upside down. 2. Unscrew the 6 screws.
7.4.
Removal of G-P.C.Board
1. Remove the connector metal fittings with the G-P.C.Board according to the section 7.3. "Removal of A-P.C.Board". 2. Unscrew the 1 screw and remove the G-P.C.Board .
3. Return the projector to the normal position. 4. Remove the upper case.
7.3.
Removal of A-P.C.Board
1. Remove the upper case according to the section 7.2. "Removal of Upper Case". 2. Unscrew the 2 screws and remove the lamp house. 3. Unscrew the 1 screw and remove the connector cover 4. Unscrew the 3 screws fixing the S-P.C.Board. 5. Unscrew the 3 screws fixing the A-P.C.Board.
7.5.
Removal of S-P.C.Board
1. Remove the upper case according to the section 7.2. "Removal of Upper Case". 2. Unscrew the 3 screws. 3. Disconnect the flexible cable and remove the S-P.C.Board.
6. Disconnect the connectors from/to the A-P.C.Board, then remove the A-P.C.Board block with the G-P.C.Board and SP.C.Board. 7. Unscrew the 8 screws and remove the connector metal fittings. Note: · The G-P.C.Board is attached on the connector metal fittings, and it is connected with the A-P.C.Board. Work carefully when removing the connector metal fittings.
7.6.
Removal of WL-P.C.Board (PTLB50NTU/E/EA only)
1. Remove the upper case according to the section 7.2. "Removal of Upper Case". 2. Unscrew the 3 screws and remove the WL-P.C.Board with wireless LAN module.