Who's Online
There currently are 5538 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Complete and very useful. Could have benefited from a little higher resolution on the schematic and layout diagrams for improved legibility.
;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
3-6. CONVERGENCE ADJUSTMENT
1. Input the dot pattern signal. Set CONTRAST to the position at which it can be seen clearly. Set BRIGHTNESS to MIN. 2. Align the R, G, B dots in the horizontal direction at the center of the screen using RV703 (H-STAT). Note: If H-CENT was changed after adjusting HSTAT, adjust H-STAT again. (The HSTAT can be changed by the H-CENT switch.) 3. Align the top and bottom of R, G, B at the center of the screen using the V-STAT (vertical static convergence) magnets. Note: After the V-STAT adjustment, always paint the magnets to lock.
I I' I I'
5. For VMC, use a 6-pole magnet to adjust so that the R and B dots are symmetrical above and below the G dot.
R (Top section) Fixed G B
(Bottom section)
6-pole magnet Perform the VMC adjustment by rotating the 6-pole magnet to the left and right without changing the opening of it.
Adjust so that the displacement of the dot is equal at the top and bottom.
A
B
A
B
6. Repeat steps 2 to 5 until the convergence becomes correct. Note: Adjusting the convergence may affect the landing. Therefore be sure to check the landing again after completing this adjustment. 7. After adjusting, paint each magnet to lock them.
14-inch
X
X
Y Good example
Y Bad example
V.STAT convergence magnet Purity BMC magnet
While maintaining the V-STAT magnet knobs A and B at the same angle (I = I'), adjust the top and bottom convergences. If A and B are asymmetrical (I = I'), it will have a negative effect; the focus may not be accurate, or the beam striking may occur. 4. For HMC, use a 6-pole magnet and adjust so that the R and B dots are symmetrical at the left and right sides in respect to the G dot.
I I' R G B
20-inch V.STAT convergence magnet
A
B A A'
Purity BMC magnet
6-pole magnet Perform the HMC adjustment by changing the opening of the 6-pole magnet.
Adjust the 6-pole magnet so that A = A'. While maintaining the I and I' angles equal, adjust the 6-pole magnet.