Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
 ;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
 ;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
3-6. CONVERGENCE ADJUSTMENT
1. Input the dot pattern signal. Set CONTRAST to the position at which it can be seen clearly. Set BRIGHTNESS to MIN. 2. Align the R, G, B dots in the horizontal direction at the center of the screen using RV703 (H-STAT). Note: If H-CENT was changed after adjusting HSTAT, adjust H-STAT again. (The HSTAT can be changed by the H-CENT switch.) 3. Align the top and bottom of R, G, B at the center of the screen using the V-STAT (vertical static convergence) magnets. Note: After the V-STAT adjustment, always paint the magnets to lock.
I I' I I'
5. For VMC, use a 6-pole magnet to adjust so that the R and B dots are symmetrical above and below the G dot.
R (Top section) Fixed G B
(Bottom section)
6-pole magnet Perform the VMC adjustment by rotating the 6-pole magnet to the left and right without changing the opening of it.
Adjust so that the displacement of the dot is equal at the top and bottom.
A
B
A
B
6. Repeat steps 2 to 5 until the convergence becomes correct. Note: Adjusting the convergence may affect the landing. Therefore be sure to check the landing again after completing this adjustment. 7. After adjusting, paint each magnet to lock them.
14-inch
X
X
Y Good example
Y Bad example
V.STAT convergence magnet Purity BMC magnet
While maintaining the V-STAT magnet knobs A and B at the same angle (I = I'), adjust the top and bottom convergences. If A and B are asymmetrical (I = I'), it will have a negative effect; the focus may not be accurate, or the beam striking may occur. 4. For HMC, use a 6-pole magnet and adjust so that the R and B dots are symmetrical at the left and right sides in respect to the G dot.
I I' R G B
20-inch V.STAT convergence magnet
A
B A A'
Purity BMC magnet
6-pole magnet Perform the HMC adjustment by changing the opening of the 6-pole magnet.
Adjust the 6-pole magnet so that A = A'. While maintaining the I and I' angles equal, adjust the 6-pole magnet.
3-6