Equipment : Oscilloscope, VHS Alignment Tape (VFMS0003H6), TV monitor 1. Insert the VHS Alignment Tape. Then turn off the power. Enter service mode by pressing and holding FF and CH DOWN buttons on VCR together for more than 5 seconds in power off condition. The power comes on. 2. Playback in SP mode. Then, press 100 button on the remote to enter EVR PG SHIFTER ADJUSTMENT mode. PG ADJUSTMENT screen will appear on the TV Monitor.
Fig. E2-1
3. Connect the channel-1 scope probe to TP3001 and the channel-2 scope probe to TP6205. Used TP6205 as a trigger 4. Adjust value so that the trailing edge of the head switching pulse is placed 6 H±0.5 H (0.38 ms±0.03 ms) before the start of the vertical sync pulse by pressing CH UP and CH DOWN buttons on the remote control.
Fig. E2-2
5. After adjustment is completed, press REC button on the remote control. Then " COMP " will appear on the TV monitor and adjusted value will be written to Memory IC (IC6005).
46
MC-Service
|