|
Who's Online
There currently are 5989 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The manual I purchased was just what I needed. I was glad to find a site where I can find so many manuals on a wide variety of products.
;
The best diagram that I used in a long time. Everything was right on te money. It was easy and fast. Iwoiuld but again when I need a service manual.
;
The manual is great help for me, i'm happy to have it,thanks
;
Very pleased with manual except that a few more details in the drawings might make the job (not yet done, tut-tut) easier. Should be adequate though. Actually I didn't have to pay for this anyway as I was given credit for another item that wasn't quite complete. Good service, then.
;
Very useful manuals, somewhere graphics not very clear!
PZ-43HV2, PZ-43HV2E PZ-43HV2U
Measuring Waveform of Pulse Module Timing Adjustment
Timing adjustment of the pulse module control signal adjusts with the sustain pulse of eighth pulse (X DRIVE) and the ninth pulse (Y DRIVE) from the back of 6SF.
Measuring point of waveform
Y DRIVE SUSOUT waveform
1SF 2SF 3SF 4SF 5SF 6SF 7SF
X DRIVE SUSOUT waveform
1SF 2SF 3SF 4SF 5SF 6SF 7SF
1ms/div Magnify 6SF block
1ms/div Magnify 6SF block
5µs/div
CH1 : Y SUSOUT Under (K2203), 50V/div CH2 : Y SUSOUT Upper (K2212), 50V/div CH4 : YPR-U1 (K2038)- Trigger, 5V/div Trigger : 2msec delay Use this sustain pulse and adjust.
5µs/div
CH1 : X SUSOUT Under (K3106), 50V/div CH2 : X SUSOUT Upper (K3105), 50V/div CH4 : YPR-U1 (K2038)- Trigger, 5V/div Trigger : 2msec delay Use this sustain pulse and adjust.
� Perform adjustment of waveform with a black mask screen. � It is easy to adjust when turned field AB offset to OFF (RS-232C command: OCN) in adjustment. Note: � Sampling rate of oscilloscope sets it more than 500MS/s in order to perform ns order adjustment. � Collecting calibration of probe before adjustment by all means. � Connect GND of probe measuring waveform to SUSGND terminal by all means. � Precise waveform is not displayed, and an adjustment gap may occur that does not collect GND properly.
When took waveform be each drive Assy unit, measure it at the fourth sustain pulse from the back except for a large width sustain pulse. Therefore, when measured both waveform of the X and Y drives together, it becomes the sustain pulse of 8 and 9 pulses from the back.
Waveform coarse adjustment
Measure the SUSOUT waveform When there is a gap with waveform of CH1 / CH2 of the part which enclosed in the following circle, adjust required VR to overlap the waveform.
1ms/div Magnify the adjustment waveform
Adjust with SUS-B CH1 : Y SUSOUT Under (K2203), 50V/div CH2 : Y SUSOUT Upper (K2212), 50V/div CH4 : YPR-U1 (K2038)- Trigger, 5V/div Trigger : 2msec delay Adjust with SUS-G
500ns/div
Adjust with SUS-U
26
|
|
|
> |
|