Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great manual, great price. Has a few of the basic operating instructions that most service manuals leave out. Complete instructions for disassembling board by board, safety precautions, schematics, complete parts list.
 ;
I am very pleased with the service manual for my RT-909. This was an easy purchase and great procuct, and much cheaper than other venues i had looked at. This web site is now listed in my favorites list. KEEP UP THE GOOD WORK. THANKS. J. BROWN
 ;
A very well written and easy to understand manual.
 ;
There was no problem at all.After paying i had to wait only a few hours,than i could
download the manual in best pdf-quality.
Thank You !
 ;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
6. PRECAUTIONS FOR REPAIR: MODULE QW-1559 / 1564 / 1565 6-1. AC (ALL CLEAR) AND REMOVING OF MODULE
1.Perform AC (ALL CLEAR) when inserting a new battery, or else the memories and/ or counters may give erratic displays. Touch the AC contact and the positive (+) side of the battery or main plate with the metalic tweezers. The contact should be made for about two seconds. For 2 seconds after the AC operation, do not make any button operations on these modules. 2.On removing of the module from the case, please insert the precision screw driver between the module and the case pointed by arrows.
Metallic tweezers
6-2. ACCURACY CHECKING
Check the accuracy of the module with the quartz timer after switching the module to "ACCURACY CHECKING MODE". The operations are shown below: A) SWITCHING TO "ACCURACY CHECKING MODE" Keep pushing the D button and continuously push the A , C buttons at the same time at the normal time keeping mode. Then all the segments are displayed and the LCD drive signals are changed to the static drive signal of "32 Hz" so that you can check the accuracy with the quartz timer. B) CANCELLATION OF THE "ACCURACY CHECKING MODE" Push any button except D . Then the display is returned to its original state. NOTE: The "ACCURACY CHECKING MODE" will automatically return to the regular mode in 1 ~ 2 hour(s) without any operation.
QW-1559 QW-1564 QW-1565