|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Dear Sirs,
Thank you for the fast support, the manual does provide all necessary information to repair the radio. All schematics are in a good quality for reading.
The manual fits 100% to my requirements as a technican.
Kind regards Thomas
 ;
the big video recorder format s-vhs many features delicate in loading system of the cassette. Such machines are no longer manufactured, it would be too expensive.
 ;
THIS MANUAL IS VERY GOOD AND VERY CLEAR
PLEASE NOTE IT DOES NOT CONTAIN THE SETUP INFORMATION TO ALIGHN THE GEARS IN THE CD MECH IT DOES SHOW ALL THE PARTS AND THEIR LOCATIONS .
 ;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
MICROWAVE MEASUREMENT
After any repair, the microwave oven must be checked for microwave leakage to ensure continued safe operation. BS EN 60335-2-25 specifies that the maximum permitted leakage with a load of 275 ml is 50 W/m2 (equivalent to 5 mW/cm2) at a distance of 5 cm from the oven.
PROCEDURE
1. Place the beaker containing the water load in the oven cavity at the centre of the turntable. The placing of this standard load in the oven is important, not only to protect the oven, but also to ensure that any leakage it is not disguised by too large a load absorbing energy. 2. Close the oven door, and with the power level set to FULL, turn the oven ON with the timer set for a few minutes operation. Should the water begin to boil before the test has been completed, it should be replaced. 3. As shown in the diagram below, move the probe slowly (not faster than 2.5 cm/sec.);a) around the edge of the door following the gap b) across the face of the door c) across any vents in the oven's sides, rear or top
PREPARATION
The following items are required to carry out this test:1. A low form of 600 ml beaker made from an electrically non-conductive material, such as glass or plastic, with an inside diameter of approximately 8.5 cm. This must contain 275 ± 15 ml of water, at an initial temperature of 20 ± 2�C. 2. A leakage detector which has been calibrated within the preceding 12 months to a stand whose accuracy can be traced to National Physical Laboratory Standards. Recommended instruments are: Apollo "XI" Celtec "A100" Before commencing the test, check that the leakage detector is functioning and adjusted according to the manufacturer's instructions, and any spacers are fitted to ensure that measurement is taken 5cm from the surface of the oven.
Dotted line indicates the path taken by the leakage detector.
Whilst the maximum leakage permitted in BS EN 60335-2-25 is 50 W/m2 (equivalent to 5 mW/cm2), it is not normal to detect any significant leakage, and therefore any detected leakage should be investigated.
R-952M - 17
|
|
 |
> |
|