Text excerpt from page 5 (click to view)
4.5
Installation
200 cm²
20 mm
IMPORTANT:
Please follow the installation details below carefully. Guarantee is valid for products installed as described only.
1. The refrigerator must be level both directions 2. There sould be 20mm clearance to the wall 3. Ventilation must be provided as shown in alternatives A,B,C or D 4. The ventilation duct must at least measure 105mm x the wtdth of the refrigerator 5. Only the entire cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7. Ventilation grills, if used, must have openings of at least 200cm² each
Where a socket outlet is used for the mains connection lead, the outlet must be freely accessible.