|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
My first manual from Owner-Manuals.com but not the last! I am very satisfied with the easy ordering and promt delivery of a manual I did not find anywhere else.
 ;
This manual is very helpfull to use the Power Supply. All technical information has been available.
For service use the circuit diagrams are very good.
Thanks .
 ;
Very comprehensive document which is a must-have for any Satellit 2100 owner whose set up is somewhat intricate. Due to the bad quality of the pictures that are rather dark and a bit blurred I gave 4-star feedback.
 ;
The manual was missing 2 pages but when I presented the problem to the company they made every attempt to get the 2 pages to me, when they couldn't they refunded my money. A very pleasing and easy transaction. The manual they provided was the original, it was concise and to the point. I plan to do business with this company again when should the need arise.
 ;
The owners manual is very good. all my how to questions were answered in detail.
MAINTENANCE
Replacing the cutting unit�s belts
Belt replacement on BioClip 103 There are two versions of BioClip 103. Version 1 has a single toothed belt and version 2 has two belts. The toothed belts drive the blades and synchronise their rotation. The belts are located under a cover on top of the cutting unit. 1. Remove the cutting unit, see page 34. 2. Remove the attachment frame, see �Removing the attachment frame�. 3. Tilt the height adjustment arm (E) forwards. Unscrew the front bolt from the parallel strut (F) and tilt the strut backwards. 4. Undo the two screws that hold the protective cover and lift off the cover. Useful hint: Mark the positions of the blades on each belt using a felt-tip pen. 5. Version 1: Unscrew the three screws 1/2 - 1 turn. Press the sides of the belt together to give maximum slack and tighten one of the screws. Replace the belt and tension it as shown (see decal on cover). Set the blades at 90° to each other and undo the screw again. The spring will set the correct belt tension. Check the positions of the blades again, and adjust if necessary by repositioning the belt on the teeth. Tighten the three screws to a torque of 45 Nm.
D C
E
B
A
F
G
BioClip 103 Version 1
5. Version 2: Loosen the nuts on the eccentric plate and turn this away. Loosen the four nuts (see diagram) holding the outer blade bearing enough so that the bearing can be moved. Slide the blade bearing in towards the centre bearing and pry off the upper belt. Repeat the procedure for the lower belt.
!
WARNING! Protect your hands by wearing gloves when working with the blades.
BioClip 103 Version 2
English �
39
|
|
 |
> |
|