Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service manual is as described and received the link to the download sooner than expected. Great service, quality product. This site is a big help in the electronics repair business.
 ;
Il service manual molto accurato. Rapidi nella risposta
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
RR 640 CD / RR 670 CD
Abgleichvorschriften / Adjustment Procedures
2. Tuner
Messgeräte: Messsender, Wobbelsender, Oszilloskop, Frequenzzähler. Funktionsschalter: Radio Abgleich 1. AM-ZF Vorbereitung Wobbelsender 465kHz über Rahmenantenne in L506 (Ferritantenne) einkoppeln. Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: MW fu 515kHz, fo 1630kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW MW 558kHz, MW 1440kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: fo 292kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW LW 153kHz, LW 261kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW Drehkoanschlag: FM fu 87,35MHz, fo 108,25MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM FM 88MHz, FM 106MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM Messsendersignal keines IC501 zwischen Pin 1 und Pin 29 kurzschlie�en. Frequenzzähler an Messpunkt TP 5 (IC501 Pin 4). Abgleichvorgang Mit T501 auf Maximum einstellen.
2. MW Oszillator
fu (bei 515kHz) mit L504 auf Maximum einstellen. fo (bei 1630kHz) mit VCT501(B) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
3. MW Vorkreis
Bei 558kHz mit L506 (MW-Antennenspule) auf Maximum einstellen (verschieben). Bei 1440kHz mit VCT501(A) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
4. LW Oszillator
fo (bei 292kHz) mit TC502 auf Maximum einstellen.
5. LW Vorkreis
Bei 153kHz mit L507 (LW-Antennenspule) auf Maximum einstellen (verschieben). Bei 261kHz mit TC501 auf Maximum einstellen. Abgleich wechselseitig wiederholen.
6. FM Oszillator
fu (bei 87,35MHz) mit L503 auf Maximum einstellen. fo (bei 108,25MHz) mit VCT501(C) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
7. FM Vorkreis
Bei 88MHz mit L502 auf Maximum einstellen (verbiegen). Bei 106MHz mit VCT501(D) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
8. FM-MPX (Stereo)
Mit VR501 76kHz ± 100Hz einstellen.
TP 6 TP 7
TP 5
TP 2
TP 1
GRUNDIG Service
2-2
|
|
 |
> |
|