GRUNDIG Service
FREAXX 40 RRCD 4204 PLL
2. Cassettenteil
Messgeräte/Messmittel: Frequenzzähler, NF-Voltmeter, Tonhöhenschwankungsmesser, Fe-Testcassette 3150Hz/8kHz (z.B. 449)
Abgleich 1. Bandgeschwindigkeit
Vorbereitung Frequenzzähler an Kopfhörerbuchse. Testcassette (z.B. 449) einlegen, 3150Hz-Teil abspielen.
Abgleichvorgang Mit dem Einstellregler (im Cassetten-Motor) 3150Hz ± 0,1% einstellen.
Bandgeschw. Tape speed
2. Gleichlauf
Tonhöhenschwankungsmesser an Kopfhörerbuchse. Testcassette (z.B. 449) einlegen, 3150Hz-Teil abspielen.
Gleichlaufabweichung < 0,35% (gehörrichtig bewertet). Wiedergabemesszeit � 30 Sekunden.
3. Kopfspaltsenkrechtstellung (Azimut)
NF-Voltmeter an Kopfhörerbuchse. Testcassette (z.B. 449) einlegen, 8kHz-Teil abspielen.
Mit der Kopfeinstellschraube 1 den linken und rechten Kanal auf Pegelmaximum einstellen. Der Pegelunterschied von Kanal zu Kanal darf maximal 3dB betragen.
1
4. Vormagnetisierungsfrequenz
Frequenzzähler an Stecker CN401 Pin2 / Pin4 (Masse). Bespielbare Cassette einlegen. Gerätefunktion: Aufnahme-Start.
Mit L401 64kHz ± 0,3kHz einstellen.
2-2
|
|
|
> |
|