This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
 ;
Well-scanned, complete manual. Contains the information needed for repair and maintenance.
SA-AK340P / SA-AK340PC
13.2. Tuner Section
This section include details on the alignment of AM-IF and AM RF adjustment.
13.2.1. AM-IF Alignment
1. Set up the equipments as shown in Fig. 5. 2. Select [TUNER] mode on selector and set to [AM] mode. 3. Apply signal as shown in Fig. 5 from AM-SG. 4. Adjust Z2602 accordingly so that the output frequency is maximized at 450kHz in Fig. 6.
Fig. 5
Fig. 6
13.2.2. AM RF Adjustment
1. Set up the equipments as shown in Fig. 7. 2. Select [TUNER] on selector and set to [AM] mode. 3. Set AM-SG to 520kHz. 4. Receive 520kHz in the unit. 5. Adjust L2601 (OSC) so that the EVM-AC is maximized. 6. Set AM-SG to 600Hz. 7. Receive 600Hz in the unit. 8. Adjust L2601 (ANT) so that the EVM-SG is maximized. 9. Set AM-SG to 520kHz. 10. Receive 520kHz in the unit. 11. Adjust L2602 (OSC) so that the EVM-DC value is with 1.1±0.5V.