SA-WSLF10/SS-CTL10/TSL10/TSL11 SECTION 4 ELECTRICAL ADJUSTMENT
DIAT SIGNAL RF LEVEL ADJUSTMENT This adjustment is performed in order to adjust the transmission distance of RF signal for DIAT communication. Connection:
oscilloscope TX board TP815 (RF AMP OUT)
Procedure: 1. Connect the oscilloscope to TP815 (RF AMP OUT) and GND on the TX board. 2. Connect DIR-T1 to DIR-T1 jack (J908). 3. Adjust RV801 on the TX board so that the center of waveform becomes trigger level 1.05 Vp-p. (*Trigger position: �4 DIV) 4. Confirm trigger is locked. 5. Adjust RV801 on the TX board so that the center of waveform becomes 2.2 to 2.4 Vp-p.
VOLT/DIV : 500 mV TIME/DIV : 500 ns
level : 2.2 to 2.4 Vp-p
RF Signal Reference Waveform
Adjustment Location:
� TX BOARD (Component Side) �
RV801 DIAT Signal RF Level Adjustment IC804 IC805
TP815 (RF AMP OUT)