This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
SCD-C222ES
Set Check
92. SET CHECK SET TEST START 10. TOTAL CHECK 120. MANUAL CHK 121. LOAD IN ? (Not used) 122. SPIN UP ?
0. IC&FL CHECK ?
11. AUTO CHECK ?
1. TOTAL CHECK ?
12. MANUAL CHK ?
2. F.JUMP CHECK ?
13. DISP RSLT ?
123. PARAMETER ?
3.HYB CHECK ?
TOTAL CHK END ?
124. READ TOC & PSP ?
4. DISP ERROR ?
125. 1/3 SEEK ?
END ??
126. 1-M SEEK ?
127. ERR RATE ?
128. HENSHIN ?
129. SPIN DOWN ? 12A. LOAD OUT ? (Not used) MAN. CHK END?
Press the [l AMS L] dial when No.sssss sssss*1 is displayed, and a checking for that display will start or the lower layer will be selected. For the selection on the same layer, rotate the [l AMS L] dial. It is looped on the same layer, and when �END?� is displayed, press the [ l AMS L ] dial to return to the upper layer. *1 s denotes a displayed character. Manual Check Method In the �12. MANUAL CHK�, individual checks (121. LOAD IN to 12A. LOAD OUT) are possible.
Example: If 124. READ TOC & PSP of 12. MANUAL CHECK is to be checked.
Setting Method: 1. After setting the test mode, rotate the [l AMS L] dial to select �92. SET CHECK� and press the [l AMS L ] dial to enter. 2. When �SET TEST START� is displayed, rotate the [ l AMS L ] dial clockwise by 2 clicks to select �1. TOTAL CHECK?� and press the [ l AMS L ] dial to enter. 3. When �10. TOTAL CHECK� is displayed, rotate the [l AMS L] dial clockwise by 2 clicks to select �12. MANUAL CHK?" and press the [ l AMS L ] dial to enter. 4. When �120. MANUAL CHK� is displayed, rotate the [l AMS L] dial clockwise by 4 clicks to select �124. READ TOC & PSP?� and press the [l AMS L ] dial to enter. 5. A checking will start automatically.
Note: In making a check, the disc must be loaded. Immediately when a check started, the tray is drawn into the set. Also, the tray can be opened/closed even during the set check mode.