Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
 ;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 ;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
 ;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
 ;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
SCD-CE775
Set Check
92. SET CHECK SET TEST START 10. TOTAL CHECK 120. MANUAL CHK 121. LOAD IN ? (Not used) 122. SPIN UP ?
0. IC&FL CHECK ?
11. AUTO CHECK ?
1. TOTAL CHECK ?
12. MANUAL CHK ?
2. F.JUMP CHECK ?
13. DISP RSLT ?
123. PARAMETER ?
3.HYB CHECK ?
TOTAL CHK END ?
124. READ TOC ?
4. DISP ERROR ?
125. 1/3 SEEK ?
END ??
126. 1-M SEEK ?
127. ERR RATE ?
128. HENSHIN ?
129. SPIN DOWN ?
12A. LOAD OUT ?
MAN. CHK END?
Press the [l AMS L] dial when No.sssss sssss*1 is displayed, and a checking for that display will start or the lower layer will be selected. For the selection on the same layer, rotate the [l AMS L] dial. It is looped on the same layer, and when �END?� is displayed, press the [l AMS L ] dial to return to the upper layer. *1 s denotes a displayed character. Manual Check Method In the �12. MANUAL CHK�, individual checks (121. LOAD IN to 12A. LOAD OUT) are possible.
Example: If 124. READ TOC of 12. MANUAL CHECK is to be checked.
Setting Method: 1. After setting the test mode, rotate the [l AMS L] dial to select �92. SET CHECK� and press the [ l AMS L ] dial to enter. 2. When �SET TEST START� is displayed, rotate the [ l AMS L ] dial clockwise by 2 clicks to select �1. TOTAL CHECK?� and press the [ l AMS L ] dial to enter. 3. When �10. TOTAL CHECK� is displayed, rotate the [l AMS L] dial clockwise by 2 clicks to select �12. MANUAL CHK?" and press the [ l AMS L ] dial to enter. 4. When �120. MANUAL CHK� is displayed, rotate the [ l AMS L ] dial clockwise by 4 clicks to select �124. READ TOC?� and press the [ l AMS L ] dial to enter. 5. A checking will start automatically.
Note: In making a check, the disc must be loaded. Immediately when a check started, the tray is drawn into the set. Also, the tray can be opened/closed even during the set check mode.