This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
No Tray open / close operation
Is the connector properly inserted into CN800 ? Y When pressing the EJECT SW, does the peak value of the IC400 5Pin become 3.3V? Y When it is in the Tray Open mode, does the IC400 6Pin show 1.65V?
N
Try the operation after inserting the connector to CN800 properly.
N
Check the SW701 patterns and the welding condition.Replace it if the condition is normal.
N
Check the SW701 Open and Close patterns and the welding condition. Replace it if the condition is normal. Y
CLOSE
Y
OPEN
When pressing the EJECT SW, does the IC500 Pin26 vary from 0V to the value between1.15V and 2.15V and then show 1.65V finally?
N
Check the condition and patterns of R615, R616. If they are normal, replace IC500.
N
When pressing the EJECT SW, does the IC500 26Pin vary from 1.65V to the value between 1.15V and 2.15V and then show 0V finally?
N
Y
Is the Tray Motor able to output the Pin49 and 50 of IC500? Y
Y
Replace TRAY MOTER.