complete part-lists and pcb layout, schematic diagram is good enlargable,
 ;
Excellent, fast delivery, excellent product. Good luck!
 ;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
 ;
Great to have extra resources for Service Manuals, Now days you can really not trouble shoot efficiently without one , Wayne at IRIONS TV & ELECTRONICS REPAIR Clearwater , Fl. 33755 727-446-7955
 ;
For five bucks you can barely buy a hamburger. Or for the same five bucks you can buy a service manual. Much more useful. (and better for your health, depending on where you buy your hamburgers).
Yes, there are free manual sites out there, but if they don't have what you want, you have to pay.
And five bucks isn't much. Not for full specs, schematics and adjustment and parts replacement procedures.
My only criticism is that grayscale illustrations aren't well rendered, but I've seen worse.
Schematics and text are clear.
I'll be happy to purchase from here again.
Mike
[email protected]
Copy image Center Within 2.0mm
b
Within 2.0mm
(Original)
Original center
a
Copy image
Center
(Duplex copy tray) When the image is shifted to direction of a, loosen two cup screws and turn the adjustment screw in the direction of A. When the image is shifted to direction of b, loosen two cup screws and turn the adjustment screw in the direction of B. After completion of the adjustment, tighten two cup screws (M4).
2mm or less (Copy)
Copy image center
2mm or less (Copy)
Center copy image
Move the lens to A.
Move the lens to B.
3 If the center shift is outside the specified range, change the lens
unit installing position back and forth.
e. Copy image center position adjustment in the RADF unit original tray mode. (The RADF unit original tray position is changed.) 1 Set the test chart on the RADF tray. 2 Select the paper feed tray unit (No. 1), and make a copy on A4
(11 � 8.5") paper in the RADF copy mode. Check for the copy image center shift.
B A
Original center
(Original)
Lens
Lens unit
3.0mm or less (Copy)
Copy image center
Center 3.0mm or less (Copy) copy image
When the lens unit installing position is changed, be sure to perform procedures a � e again. Be sure also to adjust the blank lamp position.
3 If the center shift is outside the specified range, change the RADF
tray unit original width adjustment guide position.
(3) Focus adjustment (No. 4/5 mirror unit reference position adjustment)
The focus adjustment is made by making a normal copy, a reduction copy, and an enlargement copy with SIM 48-1 (48E, 48D, 48F) and checking focus. When replacing the lens or in the case of memory trouble, however, the method by making copy and checking focus and entering the adjustment value is not efficient. In that case, calculate the input value depending on the value displayed on the lens and the table, enter the adjustment value temporarily with SIM 48-3, make copies with SIM 48-1 (48E, 48D, 48F), check the focus, and enter the final adjustment value.
Loosen the screw.
I. Focus adjustment value input (Temporal adjustment value input)
Enter the input for each of the normal copy, the enlargement copy, and the reduction copy with SIM 48-3.
f. Change the lens unit position back and forth. (All copy modes)
This adjustment is made only when the copy image center shift adjustment cannot be completed with procedures a � e.
Normally this adjustment is not required. In this adjustment, the input value is calculated depending on the value displayed on the lens and the formula and the table, and it is set. Therefore, the adjustment value to be entered is not the final adjustment value. It is only a temporary value. When replacing the lens or in the case of memory trouble, however, the method by making copy and checking focus and entering the adjustment value is not efficient.
1 Set the test chart on the original table using the mark on the
original stopper as the reference.
2 Select the paper feed tray unit (No. 1), and make a copy on A4
(11 � 8.5") paper. Check for the copy image center shift.
6 � 31
|
|
 |
> |
|