Complete manual with clear schematic diagrams and printed circuit board layouts of two variants of the headset and the transmitter an old and a new version.
Also shows how the headset and the transmitter is opened and how transmitter and receivers can be adjusted and where to measure.
I had no problems to repair the headset using this service manual.
 ;
Excellent printing quality. A complete and very useful manual with all details.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
SF-2540 Main code 52 Sub code 01 Description Ref. Page
°
ADU alignment plate adjust value setup Used to adjust the home position of the ADU alignment plate. When the test command is executed, the READY lamp turns on. Enter a new value as the previously set value came displayed, and press the PRINT switch to stored it in memory. It is adjustable from 1 to 99. The default is 7. Setting a smaller value increases the width of the alignment plate and vice versa. ADU rear plate adjust value setup Used to adjust the home position of the ADU rear plate. When the test command is executed, the READY lamp turns on. Enter a new value as the previously set value came displayed, and press the PRINT switch to stored it in the memory. It is adjustable from 0 to 99. The default is 0. Setting a smaller value increases the width of the rear plate and vice versa.
02
°
03
ADU drive clutch off time setup: 1ms increment (1 step) 0 � 10 1 = 1ms, ��� 18 = 18ms, ��� 99 = 99ms Setting a smaller value shortens the ADU clutch off timings and decreases the enforced curling rate of paper.
53
01
°
RADF stop position adjustment value (normal paper, single copy) setting Used to adjust the RADF stop position in single copy with normal paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (normal paper, duplex copy) setting Used to adjust the RADF stop position in duplex copy with normal paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (thin paper, single copy) setting Used to adjust the RADF stop position in single copy with thin paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (thin paper, duplex copy) setting Used to adjust the RADF stop position in duplex copy with thin paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF resist sensor adjustment Used to adjust the RADF resist sensor. (In the case of ADF, the resist sensor and the paper pass width sensor are adjusted.) When this simulation is executed, the RADF resist sensor is adjusted and the adjustment value is displayed.
02
°
03
°
04
°
05
°
06
°
RADF timing sensor adjustment Used to adjust the RADF timing sensor. When this simulation is executed, the RADF timing sensor is adjusted and the adjustment value is displayed. RADF repulsion sensor adjustment Used to adjust the RADF repulsion sensor. When this simulation is executed, the RADF repulsion sensor is adjusted and the adjustment value is displayed. RADF empty sensor adjustment Used to adjust the RADF empty sensor. When this simulation is executed, the RADF empty sensor is adjusted and the adjustment value is displayed.
07
°
08
°
8 � 17
1/27/1999