Setup example If the lead edge of the original was still not to the stopper, enter an optimum value.
Original Stopper Glass
(2)
If the image at the lead edge of the original were to deform, enter an optimum value to move to the glass side.
Original Stopper Glass
(3)
If the original were to override the stopper, enter an optimum value to move it to the glass side.
Original Stopper Glass
After finished selecting settings using test command 53; the screen shown in the illustration bellow will appear. Select one of the numbers from this screen then use the 10-key pad to enter a setting for items #1 through #15. SIMULATION No. 53 01 � 04: ORIGINAL STOP POINT SETUP. NOM 1 2 3 4 * * * * * * THIN SIMP * * DUP
05 � 06: (NO PROGRAM) 07 � 10: RADF SENSOR ADJUSTMENT. 07.REGIST 08.TIMING 09.EXIT REVERSAL 10.EMPTY
C 5
3
1~4
Set to between 0 and 15 as dictated by the copier's performance. The factory setting is "8".
�4�
|
|
 |
> |
|