5-2 Initial
Initial Failure
Downloading SW is OK ? (Is CSROM signal OK ?)
No
After power on, check and repair the important signals of U108 as follows
Yes
The node between R162 and C183 = "H" (RST)
No
Check the circuit related to reset
Yes No
R114 = "H" (BOOT) Resolder R114
Yes
Check all the other connection by Test S/W R150 = "H" (GPIO4)
No
Resolder R150
Yes
Check the circuit around LCD
No
R165 = "L" (GPIO2) Resolder R165
Check the circuit around U107(EEPROM) and data stored in it Replace PBA
END