SJ-42F-GY/WH SJ-45F-GY/WH SJ-48F-GY/WH
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set. Because these are important for maintaining the safety of the set.
CONNECTED IN TERMINAL BOX
G
: GRAY CONNECTOR
Br : BROWN O Y R P B : ORANGE : YELLOW : RED : PINK : BLUE (Br)
TIMER
(R) THERMOSTAT
TM
(G)
Bk : BLACK S-B : SKY-BLUE G-Y : GREEN-YELLOW INTERIOR LIGHT L FAN MOTOR FM (S-B) SOURCE CORD (O) (P) 3P. PLUG DOOR SWITCH (G-Y)
(Y)
DEFROST HEATER
THERMO. FUSE
OVERLOAD RELAY DRAIN HEATER (Bk)
DEFROST THERMOSTAT
(Bk) STARTING RELAY 2 (B) 5 6 C M
A
COMPRESSOR
Except for SJ-48F
Figure W-1. Wiring Diagram
5
|
|
 |
> |
|
|