Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
 ;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
 ;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
SJ-P58M/58M SJ-P63M/63M SJ-P68M/68M
(3) Setting of Fan motor ass'y , Defrost thermo. ass'y and Fuse ass'y
E.V cover Tapping screw
E.V cover sealer C
E
L-band C
Lead E.Vcover ass�y more than 3.5mm more than 3.5mm Tapping screw Aluminum tape
Defrost thermo. ass�y
E Set metal side below
[FRONT SIDE]
Aluminum tape
Take out lead wire from square hole to front, and seal with E.V cover sealer C.
F
F
Fuse ass�y Defrost thermo. ass�y
ATTENTION
cut
E.V cover Fuse ass�y
Turn up is lead wire
Not come out of claw
Sec. F-F
Sec. E-E
Figure A-17 (4) Inserting of pins
Fan motor 1 , 2
WIRE COLOR FOR FAN MOTOR
F-thermostat 3 (RED, inserted)
100-110V : WHITE 127V : YELLOW 220-240V : BLUE
F-thermostat 4 (BROWN, inserted) Defrost thermo. 5 (PINK) Defrost thermo. 6 (BLUE)
1 4
2 5
3 6
Fan motor 9 Fuse 8 (WHITE) Fuse 7 (BLACK)
10 5mm
7
8
9
Note
Pins should be inserted surely, and check by pulling it.
Figure A-18
After inserting, fix with vinyl tape.
Vinyl tape
60 m m
Figure A-19
25
+