Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
 ;
I really like this manual and it's reliable.I found and bought easly.thank you.
SKW-204 ADJUSTMENT PROCEDURE
ADJUSTMENT OF IDLING CURRENT
[When] 1. Exchange transistors (Q505 - Q519). 2. Exchange MAIN PC board ass'y (NAAF-8829). [Procedure] <Note> No speaker load and No input signal. 1. Short test point P631 for amplifier is under active mode. 2. Adjust the trimming resistor R544 so that the reading of multimeter becomes 52 ohm to 53 ohm. 3. Connect the DC voltmeter to test point P531. <Fig-1> 4. Connect the AC power cord into a wall outlet. 5. Press POWER button to turn on the unit. 6. Confirm the voltage of above point after 6 minutes to 8 minutes. (Heat running) 7. When less than 3.20 mV : Readjust the trimming resistor above so that the voltage becomes 4.5 mV to 5.0 mV. When 3.30 mV to 5.20 mV : Not necessary to adjust. When 5.21 mV to 10.0 mV : Readjust the trimming resistor above so that the voltage becomes 5.0 mV to 5.5 mV. When 10.1 mV to 20.0 mV : Readjust the trimming resistor above so that the voltage becomes 5.6 mV to 6.0 mV. 8. Press POWER button to turn off the unit. 9. Disconnect the DC voltmeter. 10. Disconnect the AC power cord from a wall outlet.
100 ohm (1/4W) DC voltmeter
<Fig-1>
Test point
Trimming resistor
Test point
R544
P531
P531
MAIN PC board ass'y "NAAF-8829"
Test point
P631
Short
|
|
 |
> |
|