Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
 ;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
 ;
Good quality service manual.The scheme is on A3 format and very readable.Thank you
 ;
Very good service-manual with clear electrical diagrams. Thanks you.
 ;
the manual is in quite good quality and it's in pdf. manual was send in less then 6h.
6-2-2(b) SKEW Adjustment Method Needed to minimize the variations in Skew of the Pickup unit and to provide optimum match with the recorded signal on the Disc. 1) Connect an Oscilloscope to the �SKEW� Test Point (See Fig. 6-5). 2) Connect Power, Open the Tray and Play the TDV-533 Disc, Chapter 14. � Set the Oscilloscope Range as follows : (Voltage ; 50mV/Div., Frequency ; 10m Sec.) 3) Adjust the Screws �A� and �B� (See Fig. 6-6) using a Hex screwdriver until you obtain a Flat Waveform and the picture is stable. Then, go to Chapter 1 and make sure the Waveform is Flat here as well. If not, you have to go back to Chapter 14 and adjust again. If you cannot obtain a Flat waveform, then the unit is defective. Note: The Deck must be in a horizontal position. Use both �A� and �B� screws to adjust.
Typical Waveform before Adjustment
Waveform after Correct Adjustment
Fig. 6-7 Envelope Waveform
6-6
|
|
 |
> |
|