Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
2-3.
2-3-1.
SERVO SYSTEM Adjustment
2-4.
VIDEO SYSTEM ADJUSTMENT
RF Switching Position Adjustment (RP-230 Board) Purpose: Adjust the interval between A ch and B ch of tape playback output. Improve the interchangeability with other tapes and sets. When it is out of order, the interval appears on the screen, the screen is disturbed. Mode Signal Measurement Point PB Alignment tape SP mode color bar CH1: VIDEO LINE OUT CH2: Pin 2 of CN261 (RP230 board) (RF SWP) Oscilloscope 6.5 ± 0.5 H (416 ± 32 µsec)
Adjust the video system in the following sequence as a rule. The color video signal supplied from the pattern generator is used as a video input signal for video system adjustment in the recording mode. Make sure that sync. and color burst signals meet requirements specified at set up of adjustment shown in Fig. 7-2-1. [Adjustment Sequence] 2-4-1. Playback Y Signal Level Check 2-4-2. Recording Chroma Level Check 2-4-3. Sync. AGC Check 2-4-4. X�tal Oscillation Frequency Check 2-4-1. Playback Y Signal Level Check (MA-315 Board)
Measuring Instrument Specified Value
Purpose: Confirm that the playback Y signal level is correct. Mode Signal Measurement point Measurement equipment Specified value PB Alignment tape SP color bar Pin #� IC201 Oscilloscope 2.10 ± 0.18 Vp-p
Adjusting Method: 1) Connect RP-230 board Pin 5 of CN261 to the GND for about 1 secont to activate the RF switching position adjustment mode. 2) Check appear �A P� on FL display. 3) Using the channel + and � buttons, adjust to 416 ± 32 µsec (6.5 ± 0.5 H). 4) Press the pause button.
Confirmation Method: 1) Confirm that the play Y level is 2.10 ± 0.18 Vp-p.
CH1 CH2 Approx. 5 Vp-p V enargement Vertical sync. signal Approx. 1 Vp-p
White (100%)
2.10 ± 0.18 Vp-p
H
Fig. 7-2-4.
CH1
CH2
6.5 ± 0.5 H (416 ± 32 µsec)
Fig. 7-2-3.