This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
 ;
Well-scanned, complete manual. Contains the information needed for repair and maintenance.
2-3.
2-3-1.
SERVO SYSTEM Adjustment
2-4.
VIDEO SYSTEM ADJUSTMENT
RF Switching Position Adjustment (RP-230 Board) Purpose: Adjust the interval between A ch and B ch of tape playback output. Improve the interchangeability with other tapes and sets. When it is out of order, the interval appears on the screen, the screen is disturbed. Mode Signal Measurement Point PB Alignment tape SP mode color bar CH1: VIDEO LINE OUT CH2: Pin 2 of CN261 (RP230 board) (RF SWP) Oscilloscope 6.5 ± 0.5 H (416 ± 32 µsec)
Adjust the video system in the following sequence as a rule. The color video signal supplied from the pattern generator is used as a video input signal for video system adjustment in the recording mode. Make sure that sync. and color burst signals meet requirements specified at set up of adjustment shown in Fig. 7-2-1. [Adjustment Sequence] 2-4-1. Playback Y Signal Level Check 2-4-2. Recording Chroma Level Check 2-4-3. Sync. AGC Check 2-4-4. X�tal Oscillation Frequency Check 2-4-1. Playback Y Signal Level Check (MA-315 Board)
Measuring Instrument Specified Value
Purpose: Confirm that the playback Y signal level is correct. Mode Signal Measurement point Measurement equipment Specified value PB Alignment tape SP color bar Pin #� IC201 Oscilloscope 2.10 ± 0.18 Vp-p
Adjusting Method: 1) Connect RP-230 board Pin 5 of CN261 to the GND for about 1 secont to activate the RF switching position adjustment mode. 2) Check appear �A P� on FL display. 3) Using the channel + and � buttons, adjust to 416 ± 32 µsec (6.5 ± 0.5 H). 4) Press the pause button.
Confirmation Method: 1) Confirm that the play Y level is 2.10 ± 0.18 Vp-p.
CH1 CH2 Approx. 5 Vp-p V enargement Vertical sync. signal Approx. 1 Vp-p
White (100%)
2.10 ± 0.18 Vp-p
H
Fig. 7-2-4.
CH1
CH2
6.5 ± 0.5 H (416 ± 32 µsec)
Fig. 7-2-3.
7-3
|
|
 |
> |
|