Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
There was no problem at all.After paying i had to wait only a few hours,than i could
download the manual in best pdf-quality.
Thank You !
 ;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
 ;
Complete manual included schematics layouts and alignment procedure, clear to read and magnify, extremely pleased with manual and owner manual . com's service
 ;
perfect, i am very satisfait for the réception of the sansui r-5l service manual, thank you very much
 ;
Thank you, this is a rare document. Few others have it, but they charge way more for a download.
Great deal (even if you have to wait a few hours to get it).
5-3 HEAD SWITCHING POINT ADJUSTMENT
1) Playback the alignment tape. 2) Press the �TEST� button on Main PCB/Function PCB to set the adjustment mode. (See Fig. 5-2 and 5-3) 3) Press the �SP/LP� button of remote control then adjustment is operated automatically. (See Fig. 5-1) 4) Turn the Power off.
5-4 NVRAM OPTION SETTING
1) NVRAM Option is adjusted at production line basically. 2) In case Micom (IC601) and NVRAM (IC605 ; EEPROM) is replaced, be sure to set the corresponding option number of the reqaired model. (If the option is not set, the unit is not operated.) 1) Press the �TEST� button on Main PCB/Function PCB to set the adjustment mode. (See Fig. 5-2 and 5-3) 2) Press the �MENU� button on the remote control about 5 seconds then option setting display is appeared. (See Fig. 5-5 and 5-6) 3) Select the option number (See Table 5-1) of corresponding model with �FF/REW/STOP/PAUSE� button on the remote control. 4) If selecting the option number is completed, press the �OK (PLAY)� button of remote control. (If �OK (PLAY)� button is pressed, the selected number is changes reversed color. ; See Fig. 5-5) 5) Press the �MENU� button of remote control again to store the option number. (�PLEASE WAIT� is displayed for a second as shown Fig. 5-6 and this setting is completed.) 6) Turn the Power off.
01 09 17 25 33 41 49 57 65
02 10 18 26 34 42 50 58 66
03 04 05 06 07 08 11 12 13 14 15 16 19 20 21 22 23 24 27 28 29 30 31 32 35 36 37 38 39 40 43 44 45 46 47 48 51 52 53 54 55 56 59 60 61 62 63 64 67 68 69 70 71 72 CNG:OK SAVE:MENU
Fig. 5-5
01 09 17 25 33 41 49 57 65
02 10 18 26 34 42 50 58 66
03 04 05 06 11 12 13 14 19 20 21 22 27 28 29 30 35 36 37 38 43 44 45 46 51 52 53 54 59 60 61 62 67 68 69 70 PLEASE WAIT
Fig. 5-6
07 15 23 31 39 47 55 63 71
08 16 24 32 40 48 56 64 72
5-5
|
|
 |
> |
|