This paper enable me, to bring this lovley Scope into Function.
Without this Page, i have no cance to make this finish.
Hans M. Knoll Germany
 ;
I used for first time this the wheat and am very thanked
 ;
This manual was exactly what i needed and could not find elsewhere. Price is not too high. Great !
 ;
ecelent I was reciver the service manual soon I fell so happy very complete 100% positive all by this store tanks atte Luis salazar
 ;
A great copy of the manual, and the only one I could find anywhere on the net! The circuit diagrams are easily readable, all component values marked and easy to see. A highly appreciated download!
[Adjustment Method (*For the VCRs Equipped with Narrow Gap Video Heads)] Set the tracking control at the center position. Set the ACE head position with X-value adjusting driver both where a maximum RF output is obtained and where the RF output decreases immediately when the 4 tracking control key is pressed. Using the tape having the version No.
Play back alignment tape KRV-52NE.(For NTSC)
* TYPE OF DRUM DZH-98A
Using the 4 and $ tracking control keys. Move the tracking control point, and check the control range where the maximum RF output can be obtained.
The control range is wide. (The RF output is almost constant within a certain range even when pressing the 4 and $ tracking control keys.)
Is the RF output maximum with the tracking control set at the center position? Yes
No
The control range is very narrow. (The RF output decreases immediately when pressing the 4 and $ tracking control keys.) Conferm the type of drum.
With the tracking control set at the center position, does the RF output decrease immediately when pressing the 4 tracking control key?
Play back alignment tape KRV-52NE. (For NTSC)
Set the tracking control at the center position. Turn the X-value adjusting driver for a maximum RF output. Turn the adjusting drive counterclockwise direction, and set it at the position where the RF output is about to decrease.
With the tracking control set at the center position, does the RF output decrease immediately when pressing the 4 tracking control key? Yes Play back the SP section of alignment tape KRV-51N2. (For NTSC)
No
Is the reproduced picture normal? Yes
No
Adjustment has been completed.
Table. 4-9