Superb rendition. Drawings (schematics) complete and unabridged. I do a great deal of vintage audio restoration. Documentation is essential for successful repairs. I have found sources over the years that offer good documentation, but rarely all that is necessary. Owner's Manuals has filled that void with complete and legible documentation. They have narrowed my "favorites" to a more manageable collection. This Denon manual in particular contained the latest revisions level, and offered alterations favorable to updating the item. The Illustrated Parts Breakdown (IPB) was well enough detailed to simplify part symbols and physical locations. You will not be disappointed!
 ;
Clear and concise. Saved me a lot of time and money.
 ;
Superb manual. Exactly what I ordered and made available in a very timely manner.
 ;
very fast detailed and accurate hope to do business again
RX Section Adjustment
1. RX Level Adjustment � Perform the adjustment at T1CH (26CH: 43.780 MHz) as a rule. Setting :
FM RF SSG HAND MAIN board TP2 TP3 (RX GND)
3. RSSI (H) Sensitivity Adjustment � Perform the adjustment at T1CH (26CH: 43.780 MHz) as a rule. Setting :
AF ocillator FM RF SSG HAND MAIN board TP2 TP3 (RX GND) output: 20 Hz
Procedure : 1. FM RF SSG condition : Carrier frequency : 43.780 MHz Modulation : 1 kHz Deviation : 3 kHz Output level : 60 dBµV (1 mV) (EMF) 2. Adjust the FL101 for the maximum reading on the level meter. Also check that the output level is within the specified values.
level meter HAND MAIN board + � TP27 (SP) TP26 (SP)
Procedure : 1. FM RF SSG condition : Carrier frequency : 43.780 MHz Modulation frequency : 20 Hz (EXT) Deviation : AM 50% Output level : 2 dBµV (1.259 µV) (EMF) 2. Use the oscilloscope to confirm the FM RF SSG input (AF) signal waveform and RSSI signal, and use the RV101 so that they are synchronized matched (duty is synchronized).
oscilloscope (DC range) HAND MAIN board + � TP9 (SIG IN) TP3 (RX GND)
RSSI WAVEFORM
Specified value: �16.6 to �8.6 dBV Adjustment Location: HAND MAIN board (See page 17)
RSSI output waveform
2. RX VT Adjustment Setting:
digital voltmeter
0V RF signal EXT signal 20Hz Adjust so that they synchronize at 0V.
+ �
TP5 (RX VT) TP3 (RX GND)
Adjustment Location: HAND MAIN board (See page 17)
Procedure: 1. The digital voltmeter connected TP5 (RX VT) to TP3 (RX GND). 2. Adjust the L102 for 0.8 V ± 0.05 V reading on the digital voltmeter. Adjustment Location: HAND MAIN board (See page 17)