Received via e-mail this PDF manual is worth the money. This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand. I have later seen the original manual and it was printed in colour, but this particular manual is black & white but scan resolution is high end quality! All drawings and pictures are presented in great detail. So, nearly perfect score in my opinion.
If you own the turntable you also should own the manual!
 ;
I was very satisfied with the service manual I ordered and downloaded. I will definitely buy again from this seller.
 ;
Great product. Recieved it fast...exactly as advertised.
 ;
Manuals were delivered promptly and were correct as advertised. No issues with the download link which was provided promptly after everything was processed. Very pleasant experience
 ;
Paid for service manual & got the download fast - worth a visit if you need a service manual
HANDSET SECTION
Note: � Apply 3.6 V dc from regurated DC power supply. � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. � Set to handset manual test mode. (Refer to page 9) TX SECTION ADJUSTMENT TX VT Adjustment Setting :
digital voltmeter
RX SECTION ADJUSTMENT RX LEVEL Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting : VOL switch : M
FM RF signal generator
+ �
TP6 (TX VT) TP30 (TX GND)
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 1 kHz Deviation : FM 3 kHz Output level : 60 dBµV (1 mV) (EMF)
level meter
+ �
Procedure : 1. The digital voltmeter connected TP6 (TX VT) to TP30 (TX GND). 2. Adjust the L52 for 0.9 ± 0.05 V reading on the digital voltmeter. RX VT Adjustment Setting :
digital voltmeter
TP26 (SP) TP27 (SP)
Procedure : 1. Adjust the FL101 for the maximam reading on the level meter. Also check that the output level is the specified values. Specified Value : �9.5 to �15.5 dBV
+ �
TP5 (RX VT) TP3 (RX GND)
RSSI Hi Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting :
AF oscillator FM RF signal generator
Procedure : 1. The digital voltmeter connected TP5 (RX VT) to TP3 (RX GND). 2. Adjust the L102 for 3.0 ± 0.05 V reading on the digital voltmeter.
Output: 20 Hz
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 20 Hz (EXT) Deviation : AM 50% Output level : 5.5 dBµV (1.88 µV) (EMF)
oscilloscope (DC range)
+ �
TP9 (SIG IN) TP3 (RX GND)
Procedure : 1. Use the oscilloscope to confirm the FM RF signal generator input (AF) signal waveform and RSSI signal, and use the RV101 so that they are synchronized (duty is synchronized).
RSSI output waveform 0V Adjust so that they synchronize at 0 V. RSSI WAVEFORM
AF oscillator EXT signal 20 Hz
Adjustment Location : hand main board (See page 15)