2. RX VT Adjustment
1 The digital voltmeter connected TP5 (RX VT) to TP3 (GND). 2 Adjust the L102 for 0.8V±0.05V reading on the digital voltmeter.
[HAND MAIN BOARD] (Conductor side)
R5 C4
TP3
C136 IC101 TP5 C61 R130 46 C141
C142
Digital voltmeter
TP5 TP3
+ �
[HAND MAIN BOARD] (Component side)
L102