It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
 ;
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
 ;
great manual readable & easy to downlaod to be recommanded
 ;
Very useful, not the best scan, but definitely readable !
HANDSET SECTION
Note: � Apply 3.6 V dc from regurated DC power supply. � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. � Set to handset manual test mode. (Refer to page 9) TX SECTION ADJUSTMENT TX VT Adjustment Setting :
digital voltmeter
RX SECTION ADJUSTMENT RX LEVEL Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting : VOL switch : M
FM RF signal generator
+ �
TP6 (TX VT) TP30 (TX GND)
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 1 kHz Deviation : FM 3 kHz Output level : 60 dBµV (1 mV) (EMF)
level meter
+ �
Procedure : 1. The digital voltmeter connected TP6 (TX VT) to TP30 (TX GND). 2. Adjust the L52 for 0.9 ± 0.05 V reading on the digital voltmeter. RX VT Adjustment Setting :
digital voltmeter
TP26 (SP) TP27 (SP)
Procedure : 1. Adjust the FL101 for the maximam reading on the level meter. Also check that the output level is the specified values. Specified Value : �9.5 to �15.5 dBV
+ �
TP5 (RX VT) TP3 (RX GND)
RSSI Hi Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting :
AF oscillator FM RF signal generator
Procedure : 1. The digital voltmeter connected TP5 (RX VT) to TP3 (RX GND). 2. Adjust the L102 for 3.0 ± 0.05 V reading on the digital voltmeter.
Output: 20 Hz
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 20 Hz (EXT) Deviation : AM 50% Output level : 5.5 dBµV (1.88 µV) (EMF)
oscilloscope (DC range)
+ �
TP9 (SIG IN) TP3 (RX GND)
Procedure : 1. Use the oscilloscope to confirm the FM RF signal generator input (AF) signal waveform and RSSI signal, and use the RV101 so that they are synchronized (duty is synchronized).
RSSI output waveform 0V Adjust so that they synchronize at 0 V. RSSI WAVEFORM
AF oscillator EXT signal 20 Hz
Adjustment Location : hand main board (See page 15)
� 14 �
|
|
 |
> |
|