Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
HANDSET SECTION
Note: � Apply 3.6 V dc from regurated DC power supply. � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. � Set to handset manual test mode. (Refer to page 9) TX SECTION ADJUSTMENT TX VT Adjustment Setting :
digital voltmeter
RX SECTION ADJUSTMENT RX LEVEL Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting : VOL switch : M
FM RF signal generator
+ �
TP6 (TX VT) TP30 (TX GND)
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 1 kHz Deviation : FM 3 kHz Output level : 60 dBµV (1 mV) (EMF)
level meter
+ �
Procedure : 1. The digital voltmeter connected TP6 (TX VT) to TP30 (TX GND). 2. Adjust the L52 for 0.9 ± 0.05 V reading on the digital voltmeter. RX VT Adjustment Setting :
digital voltmeter
TP26 (SP) TP27 (SP)
Procedure : 1. Adjust the FL101 for the maximam reading on the level meter. Also check that the output level is the specified values. Specified Value : �9.5 to �15.5 dBV
+ �
TP5 (RX VT) TP3 (RX GND)
RSSI Hi Adjustment Note: � Perform the adjustment at TEST1CH (26CH: 43.780 MHz) as a rule. Setting :
AF oscillator FM RF signal generator
Procedure : 1. The digital voltmeter connected TP5 (RX VT) to TP3 (RX GND). 2. Adjust the L102 for 3.0 ± 0.05 V reading on the digital voltmeter.
Output: 20 Hz
TP2 TP3 (RX GND) Carrier frequency : 43.780 MHz Modulation : 20 Hz (EXT) Deviation : AM 50% Output level : 5.5 dBµV (1.88 µV) (EMF)
oscilloscope (DC range)
+ �
TP9 (SIG IN) TP3 (RX GND)
Procedure : 1. Use the oscilloscope to confirm the FM RF signal generator input (AF) signal waveform and RSSI signal, and use the RV101 so that they are synchronized (duty is synchronized).
RSSI output waveform 0V Adjust so that they synchronize at 0 V. RSSI WAVEFORM
AF oscillator EXT signal 20 Hz
Adjustment Location : hand main board (See page 15)
� 14 �
|
|
 |
> |
|