Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
 ;
I had been looking for a Manual for my CS2150 for quite a while -- in fact I had just about given up. I saw this site and decided to download the Manual. When I Received it by Email I was really pleased with what I got, with the result that My Kenwood 'Scope is now 100% repaired and working well. As an AV Serviceman, you need a good 'scope, and thanks to this site, and the Service Manual, I have been able to repair it. The Manual was a copy of the Factory Original and the copy was very clear, especially in the area of the Circuit Schematics, where You really need to be sure of what You are looking at.
2) HANDSET
1. Test Mode Entry� Press �PGM� key and enter � TEST� on keypad. Alternative entry� Write 99h into LSB of location 9 in EEPROM. Exit� Press on �OFF� key. LCD test� Press the �7� key. Toggle TX power� Press the �0� key. Increment RF channel� Press the �#� key. 2. Test Equipment Required and Connection
3) BASE UNIT
1. Test Mode Entry� Simultaneously press the �HANDSET LOCATOR� key and toggle the �DIAL MODE� switch. When in test mode, the �IN USE� and �CHARGE� LEDs will be light on. Alternative entry� Write 99h into LSB of location 9 in EEPROM. Exit� Remove the AC power adaptor. Toggle TX power� DIAL MODE switch (S4001) T (TONE) position : TX ON P (PULSE) position : TX OFF Increment RF channel� Press the �HANDSET LOCATOR� key. 2. Test Equipment Required and Connection
C1029 C1030 � RF UNIT (HS) � J1 frequency counter � BASE MAIN BOARD (SIDE B) � � BASE MAIN BOARD (SIDE A) � frequency counter
� HAND MAIN BOARD � J1003
*
BATTERY 3.6V 48pin U1001
*
C1031 � RF UNIT (BU) �
J1 J1004
frequency counter
frequency counter
C4016 C4014 U4001 48pin
3. Verify Procedure Item 18.4MHz Frequency Error
Remark Connect the frequency counter to the test point J1, press �0� key to turn on the TX power. Then, check the frequency ± 1 kHz. If the result is within ± 1 kHz, then no adjustment required. Otherwise, refer to item 4. for Adjustment Procedure.
C4017
4. Adjustment Procedure Item 18.4MHz Frequency Error Adjustment Element C1030 Remark 1. Remove C1031 from the HAND MAIN board. 2. Solder an 20PF chip capacitor C1030 (1-164-160-11) on the HAND MAIN board (in parallel of C1029). 3. Connect the frequency counter to the U1001 pin rk. Adjust for 0 Hz ± 1 kHz.
3. Verify Procedure Item 18.4MHz Frequency Error
Remark Connect the frequency counter to the test point J1, press �0� key to turn on the TX power. Then, check the frequency ± 1 kHz. If the result is within ± 1 kHz, then no adjustment required. Otherwise, refer to item 4. for Adjustment Procedure.
4. Adjustment Procedure Item 18.4MHz Frequency Error
Adjustment Element C4016
Remark 1. Remove C4017 from the BASE MAIN board. 2. Solder an 20PF chip capacitor C4016 (1-164-160-11) on the BASE MAIN board (in parallel of C4014). 3. Connect the frequency counter to the U4001 pin rk. Adjust for 0 Hz ± 1 kHz.
�3�
�4�