Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
 ;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
8. With R and YL adjusted to be within each smaller area, check that the luminance points of MG, B, G, and CY are also partly within the range of each color reproduction. When there are spots out of the range, make adjustment by performing steps 4 to 7 so that all the luminance points are within each range.
2-4. Correction of Residual Point Noise
1. Connect one end of the RS-232C cable to the COM (RS-232C) port of the PC and other end to the connector (CN1) on the adjusting tool board. 2. Connect the adjusting tool board (CN205/PC-2001 board) to the camera and turn on the power. 3. Start the PC. 4. After starting the PC, start the adjustment software �BoxCam.exe�.
2-3-6. Writing
1. After completing the adjustment, press the TAB key to make the END button active state. (Refer to Section 23-3, Step 1) 2. After the END key becomes active state, press the Enter key. The writing of adjustment data is executed. The writing will be completed in about 5 seconds. 3. After the message for the completion of writing is displayed, turn off the power of the unit. Press the OK button of the message to clear the message.
4. Disconnect the camera from the harness of the adjusting tool board, then turn on the power of camera to check that the writing of adjustment data has been correctly completed.
5. In �SelectCOM�, select the port to which the RS-232C cable is connected. 6. Click the �Defect Compensation Mode� button. The current data is read from the camera. 7. After completion of the reading, the following message is displayed.
SSC-M183/M183CE/M188CE/M383/M383CE/M388CE SSC-DC193/DC193P/DC198P/DC393/DC393P/DC398P