Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the 2nd time I download manuals from this website and I can say it's what I was expecting. It contains schematic, layout (decent quality), short description, parts and dissasembly instructions. I recomend it for anyone who wants to repair/modify this device.
 ;
Very useful Service Manual! With it I was able to identify the damaged pots in my old amplifier, purchase the adequate replacements and make myself the repair.
I have again my old amplifier, still a very good one that I will keep for as many years as I can!
Thanks to Owner Manuals!
 ;
Good price for the manual and easy to locate on the site and download. Plus, just like the original. Thanks a lot.
 ;
Genuine Service Manual. Link was available in less then an hour or so. Service Manual contains assembly, PCB layout, complete circuit diagram, Components list etc
 ;
Great and very well scanned Service Manual, also very fast download - Recomended !
8. With R and YL adjusted to be within each smaller area, check that the luminance points of MG, B, G, and CY are also partly within the range of each color reproduction. When there are spots out of the range, make adjustment by performing steps 4 to 7 so that all the luminance points are within each range.
2-4. Correction of Residual Point Noise
1. Connect one end of the RS-232C cable to the COM (RS-232C) port of the PC and other end to the connector (CN1) on the adjusting tool board. 2. Connect the adjusting tool board (CN205/PC-2001 board) to the camera and turn on the power. 3. Start the PC. 4. After starting the PC, start the adjustment software �BoxCam.exe�.
2-3-6. Writing
1. After completing the adjustment, press the TAB key to make the END button active state. (Refer to Section 23-3, Step 1) 2. After the END key becomes active state, press the Enter key. The writing of adjustment data is executed. The writing will be completed in about 5 seconds. 3. After the message for the completion of writing is displayed, turn off the power of the unit. Press the OK button of the message to clear the message.
4. Disconnect the camera from the harness of the adjusting tool board, then turn on the power of camera to check that the writing of adjustment data has been correctly completed.
5. In �SelectCOM�, select the port to which the RS-232C cable is connected. 6. Click the �Defect Compensation Mode� button. The current data is read from the camera. 7. After completion of the reading, the following message is displayed.
SSC-M183/M183CE/M188CE/M383/M383CE/M388CE SSC-DC193/DC193P/DC198P/DC393/DC393P/DC398P