|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was very satisfied with the service manual I ordered and downloaded. I will definitely buy again from this seller.
 ;
Great product. Recieved it fast...exactly as advertised.
 ;
Manuals were delivered promptly and were correct as advertised. No issues with the download link which was provided promptly after everything was processed. Very pleasant experience
 ;
Paid for service manual & got the download fast - worth a visit if you need a service manual
 ;
It's the manual, I am searching for. Now I am able to repair my Braun A501.
4-4-9. Color Reproduction
1 Press the step forward button once. The mode indicator will display �03�. 2 Shoot the color bar chart. 3 Adjust the lens iris so that the VIDEO-OUT white image level is set to 90 ± 2.5 IRE (NTSC) or 630 ± 15 mV (PAL).
Subject Measurement point Equipment Display Mode Specification Color Bar Chart White image level of VIDEO OUT Waveform Monitor 03 90 ± 2.5 IRE (NTSC) 630 ± 15 mV (PAL)
4-4-10. WB Data Take-in
1 Press the commander�s step forward button once. The mode indicator will display �63� and the data indicator will displays �02�. 2 Shoot the all-white pattern. 3 Adjust the lens iris so that the image level of the VIDEO-OUT value is set to 65 ± 3 IRE (NTSC) or 455 ± 20 mV (PAL).
Subject Measurement point Equipment Display Mode Specification All white pattern White image level of VIDEO OUT Waveform Monitor 63 65 ± 3 IRE (NTSC) 455 ± 20 mV (PAL)
White Image Level
4 Press the data up button of the commander so that the data indicator displays �03�. 5 Make sure that the data indicator of the commander automatically displays �FF�. * If the data indicator does not display �FF�, there may be a defective part in the circuit. Repair it, then repeat these steps.
4-4-11. Data Write
4 Switching the mode between �03�, �04�, �05� and �06� by pressing the MODE DISPLAY CHANGE button and while doing so, press the data change button so that the center of the bright spot for each color is placed in it�s respective reproduction range.
Subject Measurement point Equipment Display Mode Specification Color Bar Chart Respective color bright spot of VIDEO OUT Waveform Monitor 03, 04, 05, 06 The center of the bright spot for each color is in it�s respective reproduction range
1 Press the step forward button of the commander once. The LCD indicator will turn off for a few seconds, then turn on. Make sure that the data indicator displays �00�. (The mode indicator should still display �63�.) * If the LCD indicator turns off and does not turns on, or the data indicator does not display �00�, there may be a defective part in the circuit. Repair it, then repeat these steps. Note: In this time, do not press the DATA write (PAUSE) button.
(a) (b) (c) (d)
(a) Moving direction of the bright spot when mode is �03� (b) Moving direction of the bright spot when mode is �04� (c) Moving direction of the bright spot when mode is �05� (d) Moving direction of the bright spot when mode is �06�
SSC-DC50A/54A SSC-DC50AP/54AP/58AP
4-7
|
|
 |
> |
|