Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
CUC 2030 / 2030 N / 2040 N / 2040 India
Abgleich / Alignment
D Abgleich
1. Chassisplatte
Me�geräte: Tastkopf 10:1, Farbbildgenerator, Spektrumanalyser oder HF-Millivoltmeter Servicearbeiten nach Austausch bzw. Reparatur: - Tuner: Abgl. 1.3
Abgleich 1.3 Tuner-AGC
Vorbereitung Spektrumanalyser oder HF-Millivoltmeter symmetrisch an Tunerkontakt 10, 11. Senderbild oder Generator über die Antenne einspeisen, 70�80dBµV.
Abgleichvorgang
Mit den Tasten "z -" oder "+ g" 102dBµV (360mVss) einstellen. Ersatzweise wird ohne Spektrumanalyser oder HF-Millivoltmeter mit den Tasten "z -" oder "+ g" das Bild so abgestimmt, da� es gerade zu rauschen beginnt. Dann Dialogzeile "AGC" über " " (DIALOG CENTER) �> "OK" soweit zurückstellen, bis das Bild wieder rauschfrei wird. �> SERVICE �> "OK" �> Service Code "8500" �> aufrufen. Dialogzeile "End" mit "with mem" beenden.
Hinweis:
Es werden in den Chassis CUC 20xx TDA 8843/8375 bzw. TDA 8843-N2/8844-N2 eingebaut. Bei dem Typ TDA 8843-N2/8844-N2 ist ein PLLDemodulator integriert und somit entfällt der AFC-Abgleich im Service Menü. Achtung! Nach einer Reparatur bzw. Wechsel des NVM (IC82005) mu� kontrolliert werden, ob der NTSC Quarz 3,58MHz bestückt ist. Bei nicht bestücktem Quarz, mu� über das Service Menü der Menüpunkt "NTSC 3,6" auf "aus" gestellt werden. �> OK �> SERVICE �> OK �> Service Code "8500" �> NTSC 3,6 "aus" und das Menü mit "with mem" verlassen
GB
Alignment
1. Chassis Board
Measuring instruments: 10:1 test probe, colour video generator, spectrum analyser or RF millivoltmeter. Service works after replacement or repair of the following modules: - Tuner: alignment 1.3
Alignment 1.3 Tuner AGC
Preparations Spectrum analyser or RF millivoltmeter symmetrical to tuner contact 10, 11. Feed in a standard test pattern or generator via the aerial, 70�80dBµV. Call up the dialog line "AGC" via " " (DIALOG CENTER) �> "OK" �> SERVICE �> "OK" �> Service Code "8500".
Alignment Process Adjust 102dBµV (360mVpp) with button "z -" or "+ g". Alternatively, without using a spectrum analyser or RF millivoltmeter, adjust the picture with button "z -" or "+ g" so that noise just appears on the screen. Then reset until the picture is again free of noise. Dialog line "End", terminate "with mem".
Note:
The CUC 20xx chassis is fitted with TDA 8843/8375 or TDA 8843-N2/8844-N2. Type TDA 8843-N2/8844-N2 has an integrated PLL demodulator so that the AFC needs not to be adjusted via the Service Menu. Attention! After repair or replacement of the NVM (IC82005) it is to be checked whether the NTSC 3.58MHz quartz is fitted. If this quartz is not inserted the menu option "NTSC 3.6" in the Service Menu must be set to "off". �> OK �> SERVICE �> OK �> Service Code "8500" �> NTSC 3.6 "off" and leave the menu with "with mem".
GRUNDIG Service
5
|
|
 |
> |
|