El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
SECTION 2 TEST MODE
DISPLAY / KEY TEST MODE Press the ENTER/NEXT and FUNCTION buttons simultaneously. Then press the MENU 1 button with the following 4 seconds to set the Test Mode. 1. The message �W3 NA (destination) � appears on the screen and a 32 cycle square wave of the subcrystal oscillator is output from Pin 24 (AUB. OUT). 2. Press any key to rotate JOG and all FL indicators light up. When you rotate JOG at this point, the display changes as follows. N all FL indicators on Nn FL pattern 1 Nn FL pattern 2 n The changes and all LED indicators light up. 3. Again press any key to set the key count check. The following display appears. 0 0 0 The numbers in order from left to right show ; the number of keys pressed, the JOG count (1 click per 4 counts), and the VOL count. (1 cycle is a count of 96.) 4. Press the Power button to reset to the factory settings. AMP TEST MODE Press the ENTER/NEXT and FUNCTION buttons simultaneously. Then press the MENU 2 button with the following 4 seconds to set the Test Mode. 1. The message �AMP TEST� appears on the screen. Press the MENU button to call up the Equalizer Curve for the Amp Test. However when the function is set to the tuner, use the MENU button to call up each tuner preset from 1 through 5. 2. Press the Power button to reset to the factory settings. MICROCOMPUTER COLD START Press the ENTER/NEXT and FUNCTION buttons simultaneously. Then press the MENU 3 button with the following 4 seconds to reset the microcomputer to the factory settings. SUBCRYSTAL TEST MODE Press the ENTER/NEXT and FUNCTION buttons simultaneously. Then press the MENU 4 button with the following 4 seconds. The message �XTAL TEST � appears on the screen and a 32 cycle square wave of the subcrystal oscillator is output from Pin 24 (AUB.OUT). In addition, a square wave of the same frequency as the subcrystal oscillator, is output from 4PIN (POWER. ON/OFF). Press the Power button to reset to the factory settings.
�5�
|
|
 |
> |
|