Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
got exactly what i ordered in a very timely manner. will use again for other manuals
 ;
I'm happy. Good quality. Very helped me with my work..............................
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
Section 3 Self Diagnostics
3-1. Error Code and Self Diagnostic functions
When the trouble occurs while setting up the system, perform the following self diagnostics according to error code contents.
Error code [E1], [E2] Cause of error, Self diagnostic proceeding and confirming (1) Perform the remedy for �error indications�. (Refer to �Error Indications� on page 74 of Operating Instructions.) (2) If �error indications� is still remaining, perform and confirm the following either self diagnostic. . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board� (page 3-4) (Perform the front panel buttons operation) . �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) (1) Perform the remedy for �error indications�. (Refer to �Error Indications� on page 74 of Operating Instructions.) (2) If �error indications� is still remaining, perform and confirm the following either self diagnostic. . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board� (page 3-4) (Perform the front panel buttons operation) . �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) n Make sure bit switch of RS-232C portion that is installed in rear panel of the unit (SX-M10), is set correctly. (Refer to Operating Instructions on page 48.) When both CPUs on the CPU-331 board could not establish a communication, the error code [E5] will be indicated. (1) Perform and confirm the following self diagnostics. . �Sec.3-2-1. Self diagnostic of the SX block on the CPU-331 board� (page 3-2) . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board that is performed the front panel buttons operation on the unit� (page 3-4), or �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) n When slide switch S3 is set to DIAG position or bit switch S2 is set to ON position on the CPU-331 board, the error code [E5] may be indicated. In this case, make sure confirm the both switches setting position. (Normally, slide switch S3 is set to NORMAL position and bit switch S2 all of eight bits are set to OFF positions.) When power of the unit (SX-M10) is turned on, the error code [__] remains indicating in case that the unit could not establish a communication to the videoconference system. (When a communication to the videoconference system is completed normally, the error indication goes off.) In this case, confirm the same remedy for error codes [E1] and [E2] as described in above. When microphone switches of the SX-C100A/D100A are set to ON, the microphone number is not indicated on the unit (SX-M10). (1) In that case, perform and confirm the following self diagnostics. . �Sec.3-2-1. Self diagnostic of the SX block on the CPU-331 board� (page 3-2) . �Sec.3-2-2. Self diagnostic of the D/C UNIT on the CPU-331 board (delegate�s and chairman's unit)� (page 3-3) n When slide switch S3 is set to DIAG position or bit switch S2 is set to ON position, the lamp of the SXC100A/D100A will blinking and microphone number may not be indicated. In this case, make sure confirm the both switches setting positions. (Normally, slide switch S3 is set to NORMAL position and bit switch S2 all of eight bits are set to OFF positions.)
[E3], [E4]
[E5]
[__] (However, in case of remains On the error code [__] after power of the unit (SX-M10) was turned on.) � (No error indication)
SX-M10