I didn't realise a manual for an early plasma TV such as the one we were gifted could be so easily obtained. No manual was supplied with it, and as senior citizens we were a little puzzled over some aspects of its use. I do not want a listing for your store credit as we are not fairly big computer users. The manual was well organised, as it should be, with its backing of the Pioneer name. The download was prompt and everything worked quite smoothly. Thank you. Gordon.
 ;
Thank you very much for the manual. It is what I needed and it will be very helpful to me. The delivery of the manual was easy and very fast. I strongly recommend this site to other users. Best regards.
 ;
Excellent!! Got what I need and very fast!! Thank You
 ;
Manual acquired with good resolution, complete in all its pages, very good policy of the folder where are saved all products purchased.
 ;
Service manual very complete and clear. It was very helpfull for my work.
CUC 7303
Abgleich / Alignment
Abgleich
Alle nicht beschriebenen Einstellelemente sind werkseitig abgeglichen und dürfen im Servicefall nicht verstellt werden. Me�geräte: Zweikanal-Oszilloskop mit Tastkopf 10:1, Farbbildgenerator, hochohmiges Voltmeter. Kontrolle und Einstellarbeiten nach Austausch bzw. Reparatur von: Netzteil: Abgleich 1 Zeilenablenkung: Abgleich 2, 3 Bildröhre oder Bildrohrplatte: Abgleich 2, 6 IC150: Abgleich 4, 5 Tuner: Abgleich 4, 5
Abgleich 1. +A Spannung
Vorbereitung Helligkeit: Minimum Voltmeter: Kathode D682 Graubalken-Testbild einspeisen. Bildschirmhelligkeit so einstellen, da� die Abstufung vom dunkelsten Graubalken zu schwarz gerade noch sichtbar ist, ca. 2,7V an IC150-(17). Mittlerer Kontrast ({). An den Me�punkten R, G, B (auf der Bildrohrplatte) Oszilloskop anschlie�en und den höchsten Schwarzwertpegel ermitteln.
Abgleichvorgang Mit Regler R654 eine Spannung von 114V (14" Orion), 105V (14" Philips), 124V (17�21") einstellen. Mit Regler UG2 (Splittrafo) an dem Me�punkt mit dem höchsten Schwarzwert eine Spannung von 105V�114V für 14" und 124V für 17�21" Bildröhren abgleichen.
Schwarzwert
2. Schirmgitterspannung UG2
105V�114V 14" 105-110V 124V 17�21"
3. Zeilenschärfe
Konvergenztestbild einspeisen. Kontrast ({) Maximum. Helligkeit so einstellen, da� sich der schwarze Testbildhintergrund gerade aufhellt. Generator mit Bildträger 38,9MHz, ca. 120mV an TunerKontakt 10, 11 einspeisen. Norm 1 über Menü (" " �> "OK") einstellen. Voltmeter: IC850-(34). Generator mit Bildträger 33,4MHz, ca. 120mV an TunerKontakt 10, 11 einspeisen. Norm 3 über Menü (" " �> "OK") einstellen. Voltmeter: IC850-(34). Normtestbild auf hohen UHF-Kanal legen und auf Programmplatz 1 abspeichern. HF = 1,5mV (64dB° V, rauschfreies Bild). Gerät mit Netzschalter ausschalten. Servicemenü mit Fernbedienung aufrufen (Gerät einschalten, dabei Taste " " gedrückt halten). Mit den Tasten "P+/P-" die Zeile "AGC ALIGN" anwählen. FuBK-Testbild einspeisen. Farbkontrast (i) Minimum. Kontrast ({) Maximum. Bildschirmhelligkeit (v) so einstellen, da� die Abstufung vom dunkelsten Graubalken zu Schwarz gerade noch sichtbar ist.
Mit dem Fokusregler UF (Splittrafo) die horizontalen Linien auf maximale Schärfe stellen.
4. Bild-Demodulator (Bildträger 38,9MHz)
Mit dem Filter F130 die Gleichspannung auf 2,5V einstellen.
Bild-Demodulator Frankreich-Norm (Bildträger 33,4MHz) 5. Tuner-AGC
Mit dem Trimmer C136 die Gleichspannung auf 2,5V einstellen. Wechselseitig wiederholen! Mit den Tasten "z - oder + g" so abstimmen, da� das Bild gerade zu rauschen beginnt. Dann wieder zurückstellen, bis das Bild gerade rauschfrei wird. Einstellung mit " " beenden.
6. Wei�wert
Regler VG (R751) und VB (R771) auf der Bildrohrplatte so einstellen, da� keine Verfärbungen in den Grauwerten sichtbar sind.