Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was very pleased with the manual I got for my amateur (ham) radio. Without it I could not figure out how to input and/or change the P/L setting on my radio. It drove me nuts as the radio was essentially useless. That all changed when my manual came. Then it took only minutes and I was done. Now my radio works fine. This is an exceptionally good resource as it's a very easy and user friendly download. Thank you very much! Dziękujemy za!
 ;
It answered my question, which was how to load the paper. I did notice that the very end of the manual was not visible.
 ;
The product manual I received was exactly what I was looking for, delivered painlessly at a very fair price. I can't ask for any more than that.
 ;
Very well done!!!!! congratulations. It was a bit longer than usual the wiating time even if it was on time (in 24 hours).
 ;
Last week I bought a second hand BAUKNECHT TRK4850 DRYER. It is a professional machine with many programs and switch options. I feared it would be a huge quest to find a manual. I was delighted when I found owner-manuals.com. After payment I received the file to download the next day already. The quality is great. I am very happy. Thanks!
but kindly the distributions of the operating programs not find in the owners manual,can you help me to understand the operating programs instructions thank you
Installation
How to calculate the effective duct length
The overall duct length will determine the duct diameter. ^ Measure the actual duct length needed to go from the dryer�s exhaust connection to the vent outlet: 1. Establish the number of elbows or bends necessary, noting the type of bend, angle and radius involved (see Table). 2. Add the additional duct length (as derived by using the values specified in the table) and the actual duct length to get the effective length. Note: Maximum effective duct lengths: 4" (100 mm) diameter 66 ft (20 m) 5" (125 mm) diameter 132 ft (40 m) 6" (150 mm) diameter 328 ft (100 m) Using the ring adapter up to an effective duct length of 33 ft (10 m) and a standard duct diameter of 4" (100 mm) will provide optimal drying times and energy consumption. Do not use the ring adapter if the effective duct length is more than 33 ft (10 m). Effective duct lengths over 66 ft (20 m) require a larger duct diameter. Longer ducts may lead to slight decreases in dryer efficiency if the necessary duct diameter is not employed.
Tips about the ductwork
� Check with your local building code to determine the maximum allowable duct length. � Use flexible metal pipe or rigid metal pipe for venting. Non-metallic flexible hose should not be used, it is a potential fire hazard. � For best drying results avoid extra long ducting with too many bends, angles or tight corners. � The shorter the exhaust ductwork, the more efficient the dryer will be. Expelled air is slowed down in the ducts due to friction against the inner walls. The shorter and smoother the inner walls are, the less friction will be created. � An elbow or bend creates more friction than a straight duct. An additional duct length factor must be added for each elbow or bend (see Table). This factor expresses the resistance of the bend in terms of a straight length of duct. The additional length factor is then added to the existing duct to give the effective length. A larger duct diameter helps reduce friction. Therefore the duct diameter and length should be increased simultaneously.