Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I had been looking everywhere for a proper service manual for this VCR. Everywhere else that has this available for download has a very light version. This is the full service manual with all aspects that would interest anyone looking for the service manual for the AIWA HV-MX100 Worldwide VHS VCR. Great quality (as always). A winner hands down. Best Quality.
 ;
Top quality manual. Covers all aspects you'd expect in a top quality service manual for this Panasonic VHS VCR. The manual resolution is high. Another top quality manual from the only site worth downloading manuals from! If you're looking for a manual for the PV-9662 VHS VCR, this is the one you'll want to get!
 ;
complete part-lists and pcb layout, schematic diagram is good enlargable,
 ;
Excellent, fast delivery, excellent product. Good luck!
 ;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
SECTION 4 ELECTRICAL ADJUSTMENTS
Precaution � Supplied voltage: 2.5 V � Switch and control position VOR switch (S401): OFF PAUSE switch (S105): OFF VOL (RV101): mechanical mid SPEED CONTROL (RV602): mechanical center POP-UP MIC switch (S302): FLAT
set
Tape Speed Adjustment Procedure: Mode: playback
Standard tape for adjusting WS-48A (3 kHz, 0 dB) 10 k �
+ �
frequency counter
Test Tape
Type P-4-A063 WS-48A Signal 6.3 kHz, �10 dB 3 kHz, 0 dB Used for head azimuth adjustment tape speed adjustment
EAR jack
0 dB=0.775 V Record/Playback Head Azimuth Adjustment Procedure: Mode: playback
test tape P-4-A063 (6.3 kHz, �10 dB) 10 k � set EAR jack
+ �
1. Play back WS-48A (tape end part) and adjust RV601 so that the frequency counter reading becomes 2,985 � 3,015 Hz. 2. Play back WS-48A tape the beginning and the end part, check that the frequency counter reading is within same standard of step1. Adjustment Location:
[MAIN BOARD] (Side B)
level meter
1. Turn the adjustment screw to obtain the maximum reading on level meter.
Note: Several peaks may appear, but take the maximum.
IC101
2. After the adjustment, lock the adjustment screw with suitable locking compound.
RV601
Adjustment Location:
RV602 IC501 S102
adjustment screw
�6�
|
|
 |
> |
|