|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
There was no problem at all.After paying i had to wait only a few hours,than i could
download the manual in best pdf-quality.
Thank You !
 ;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
 ;
Complete manual included schematics layouts and alignment procedure, clear to read and magnify, extremely pleased with manual and owner manual . com's service
 ;
perfect, i am very satisfait for the réception of the sansui r-5l service manual, thank you very much
 ;
Thank you, this is a rare document. Few others have it, but they charge way more for a download.
Great deal (even if you have to wait a few hours to get it).
SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback/erase head pinch roller rubber belts capstan idlers 2. Demagnetize the record/playback/erase head with a head demagnetizer. (Do not bring the head demagnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Torque Measurement Mode FWD CQ-102C FWD Back tension REV CQ-102RC REV Back tension FF, REW CQ-201B Torque Meter Meter Reading 35 � 80 g � cm (0.49 � 1.11 oz � inch) 1 � 7 g � cm (0.012 � 0.097 oz � inch) 35 � 80 g � cm (0.49 � 1.11 oz � inch) 1 � 7 g � cm (0.012 � 0.097 oz � inch) more than 40 g � cm (more than 0.56 oz � inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
PRECAUTION
1. The adjustment should be performed in the publication. (Be sure to male playback adjustment at first.) 2. The adjustments and measurement should be performed for both L-CH and R-CH. � Switch position DOLBY NR switch : OFF DIRECTION switch : A Standard Input Level Input terminal source impedance input signal level Standard Output Level Output terminal load impedance output signal level Test Tape Type P-4-A100 P-4-L300 WS-48A Signal 10 kHz, �10 dB 315 Hz, 0 dB 3 kHz, 0 dB Used for Azimuth Adjustment PB Level Adjustment Tape Speed Adjustment TAPE OUT (L-CH) 47 k� 0.49 V (� 4 dB) TAPE IN 10 k� 0.49 V (� 4 dB)
0 dB = 0.775 V
� 13 �
|
|
 |
> |
|