This is the correct service manual of SHARP RX-100H(BK) DAT.
 ;
The ervice manual for my 1982 Kenwood KR-1000 receiver is great! Full detail on all circuits with part number detail. I will definately be ordering more manuals for my other vintage equipment! Order was fulfilled quickly! Very efficient ordering process! Thnaks for your help! Great site!
 ;
Everything in the manual was excellent except for a couple of pictures of specific areas in the unit that were a little dark. Owners Manuals re-sent the pdf file & the problem was corrected. Excellent product! George
 ;
Thanks for offering this item at such a good price. Proved handy in identifying the part I was looking for my set.
Thanks again.
3.) The image displayed with picture noise issue. Press �INPUT� button to re-catch the signal again. Check the signal cable. Check Main BD if there is no picture noise issue when you input the signal with the other connector.
Judge Change Main board. 4.) The image displayed with Dead Pixel/Line issue. Check the DMD chip if the bright dot issue when you input the signal. Judge Change DMD board or DMD chip. 5.) The image displayed with focus issue. Adjust the focus ring. Ensure the projection distance is in spec. Judge Change Optical Engine Module 6.) The image displayed with flicker issue. Check the Lamp Module Ensure the signal cable works well. Press �INPUT� button to re-catch the signal again. Judge Change Main board or DMD board. 7.) The image displayed with uniformity issue. Ensure the projection lens is clean. Replace the lamp if the brightness is less than spec. Judge Change the Optical Engine Module. 8.) The image displayed with line bar issue. Check if the line bar issue that can be fixed by �Frequency� function of OSD menu or not. Judge Change Main board.
3-8
|
|
 |
> |
|