file:///E:/aa/UM/ALL/TH-50PHD30BX/SVC/s0102000000.html
1.2 Touch-Current Check
TOP PREVIOUS NEXT 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1. 3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reserve the AC plug in the AC outlet and repeat each of the above measure. 6. The potential at any point (TOUGH CURRENT) expressed as voltage U1 and U2, does not exceed the following values: For a. c.: U1 = 35 V (peak) and U2 = 0.35 V (peak); For d. c.: U1 = 1.0 V, Note: The limit value of U2 = 0.35 V (peak) for a. c. and U1 = 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0 mA d. c. The limit value U1 = 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz. 7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer.
Figure 1. Measuring network for TOUCH CURRENTS
file:///E:/aa/UM/ALL/TH-50PHD30BX/SVC/s0102000000.html (1 z 2) [2007-04-26 12:45:37]
|
|
 |
> |
|