Very good manual, in depth and complete. Only criticism is that some of the circuit diagrams are slightly blurry and hard to follow for long periods of time, but this is to be expected. Perfect for any maintenance required. Also contains the wiring diagrams of the control cable for constructing extensions.
 ;
Received a quick response, material was exactly what it was supposed to be. The service did everything I expected it to do. would use service again.
 ;
Detailed SONY CFD980 Service Manual at an easy to find one stop shopping. Make my radio hobby technically interesting. Thanks.
4.6
Upgrading of firmware (DVD UPGRADE)
The latest firmware for upgrading is updated in "Optical disc CSG" page in JS-net. At the time of service, compare the version of the product and the latest version, and upgrade the old version into the latest version. (1) Press "STANDBY/ON" key of the main body to turn it on. (2) Push "OPEN/CLOSE" key of the main body, and insert the upgrade disc in the tray. (3) When reading the data of the disc, the OSD screen is displayed "VERSION UP DISC", "PROGRAM & DESTINATION MODE" and "READING..". (4) When the screen changes from "READING.." to "WRITING..", upgrading starts. (5) After writing the data of the disc, the screen is displayed "OPEN". (6) Take out the disc, and press "STANDBY/ON" key of the main body. (7) When the stand-by indicator is lighted, upgrading is completed. (8) Set the main body at test mode, and confirm the version of the firmware. (Refer to "4.2 Method of displaying version firmware".) 4.7 Upgrading of system microcomputer (ROM CORRECTION)
(1) Press "STANDBY/ON" key of the main body to turn it on. (2) Push "OPEN/CLOSE" key of the main body, and insert the upgrade disc in the tray. (3) When reading the data of the disc, the OSD screen is displayed "VERSION UP DISC", "SYSCON UPG MODE" and "READING..". (4) When the screen changes from "READING.." to "WRITING..", system data is written. (5) After writing the data of the disc, the FL display of the main body is displayed "COMPLETE". (6) Take out the disc, and press "STANDBY/ON" key of the main body. (7) When the stand-by indicator is lighted, upgrading is completed. (8) Set the main body at test mode, and confirm the version of the system microcomputer. (Refer to "4.2 Method of displaying version firmware".)
MENU key (switch of mode)
FL display
STANDBY/ON key
OPEN/CLOSE key (for upgrading of system microcomputer and firmware)
AV COMPULINK terminal AV COMPULINKterminal
1-28 (No.MB236)