Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
 ;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
 ;
Impeccable, document très complet. Perfect, i get all i need. All schematic are correct. Thanks
 ;
The manual is of better quality compared to other. I found it less expensive and therefore it it is the best buy cost vs quality.
 ;
I bought the service-manual of the sony ICB-1020(an old transmitter-receiver) at "www.Owners-Manual.com", I found the service-manual for a fairly cheap price(in comparison with other sellers). I filled in some questions, payed the order with Ideal, and within 24 hours I had my service manual. I was very happy:In no time I had my service-manual and everything, but literally everything was noted down in the manual; the electronic scheme, the parts list, etcetera.
A very practical, reference-document.
TK-3130/3131
ADJUSTMENT
Required Test Equipment
1. Stabilized Power Supply
1) The supply voltage can be changed between 0V and 10V, and the current is 3A or more 2) The standard voltage is 3.8V
7 Antenna
Switches
2. DC Ammeter
1) Class 1 ammeter (17 ranges and other features). 2) The full scale can be set to either 300mA or 3A. 3) A cable of less internal loss must be used.
1 5
8
3. Frequency Counter (f. counter)
1) Frequencies of up to 1GHz or so can be measured. 2) The sensitivity can be changed to 500MHz or below, and measurements are highly stable and accurate (0.2ppm or so).
2 3 Microphone 4 Speaker 6
4. Power Meter
1) 2) 3) 4) Measurable frequency : Up to 600MHz Impedance : 50�, unbalanced Measuring range : Full scale of 3W or so A standard cable (5D2W 1m) must be used. q w e r t y u i PTT (Push to Talk) switch MENU key CAL key / keys Power switch/Volume control MON key LED indicator SP/MIC jacks
5. RF Voltmeter (RF V.M)
1) Measurable frequency : Up to 600MHz or so
6. Linear Detector
1) Measurable frequency : Up to 600MHz or so 2) Characteristics are flat, and CN is 60dB or more
7. Digital Voltmeter
Adjustment Frequency List
CH Center Low High TX frequency (MHz) RX frequency (MHz) 465.050 460.050 469.950
1) Voltage range : FS=10V or so 2) Input resistance : 1M� or more
8. Oscilloscope
1) Measuring range : DC to 30MHz 2) Provides highly accurate measurements for 5 to 25MHz.
9. AF Voltmeter (AF V.M)
1) Measurable frequency : 50Hz to 1MHz 2) Maximum sensitivity : 1mV or more
When you set up above frequencies, you must use the TEST mode in the FPU.
10. Standard Signal Generator (SSG)
1) Maximum frequency : 600MHz or more 2) Output : �133dBm/0.05µV to 7dBm/501mV 3) Output impedance : 50�
11. Dummy Load
1) 8�, 1W or more
12. AF Generator (AG)
1) Frequency range : 100Hz to 100kHz 2) Output : 0.5mV to 1V
13. Distortion Meter
1) Measurable frequency : 30Hz to 100kHz 2) Input level : 50mV to 10Vrms
20
|
|
 |
> |
|