TK-860G/862G
Receiver Section
Center Frequency 49.95MHz
TK-860G/862G
LEVEL DIAGRAM
450kHz
Audio Frequency
To make measurements in the RF section, connect the RF level meter. In the RF section, use a 0.01µF coupling capacitor. (The display shows the SSG input value required to obtain 12dB SINAD.) To make measurements in the AF section, connect the AC level meter. (ANT input : �53dBm, 1kHz FM, 3kHz DEV (Wide) / 1.5kHz DEV (Narrow)) The AF output level is adjusted for 0.45V/4� by the front panel AF VOL control.
Transmitter Section
Control Unit TX-RX Unit VCO Unit TX-RX Unit Power Module TX-RX Unit
To make measurements in the AF section, connect the AC level meter. AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
To make measurements in the RF section, connect the RF wattmeter (50�).