Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> TURBO >> TL18GR/56,2A 1M INOX Owner's Manual
 
 0 item(s) in your cart 

TURBO TL18GR/56,2A 1M INOX
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English, German, French, Italian, Spanish, Russian
Price: $4.99

Description of TURBO TL18GR/56,2A 1M INOX Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English, German, French, Italian, Spanish, Russian

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 STGT1000 TECHNICS Owner's Manual by james burns;
I AM HIGHLY IMPRESSED BY THE EASE OF USE OF THIS DOWNLOAD SERVICE. INSTRUCTIONS ARE CLEAR AND SIMPLE TO FOLLOW....EVEN BY TECHNOPHOBES SUCH AS MYSELF. THE EMAILS POINT YOU IN THE RIGHT DIRECTION...ITS SO EASY PEASY. THE DOWNLOAD CHOICE OF USER MANUALS IS EXTENSIVE AND I COULD NOT FIND A CHEAPER OR MORE EFFICIENT SERVICE ON THE INTERNET. I COULD NOT HAVE MADE A BETTER CHOICE OF INFORMATION PROVIDER. SHOULD I EVER NEED ANOTHER USER MANUAL, THEN THIS IS THE FIRST CHOICE SITE. COULD NOT BE BETTER PLEASED!!!!!!!...MANY THANXES FROM JIM BURNS
 NV-DS30B PANASONIC Owner's Manual by John Richardson;
I was impressed with the quality of service (frequent e-mails to let you know the status of your order), and the speed at which the download became available. The manual was a life saver and was not easy to track down. Thank you for such an excellent service.
 A-P510 PIONEER Owner's Manual by edward lowes;
the manual was just what i wanted it had all the revelent information required to operate the hifi .Iwould use any manual i downloaded for any item which needs a manual
 TRK 5840 BAUKNECHT Owner's Manual by Lutz Döring;
Die gewünschte Bedienungsanleitung wurde vereinbarungsgemäß in deutsch bereitgestellt. Sie ist gut lesbar. Kein Kauderwelsch. Danke für den Service.
 CDP-C245 SONY Owner's Manual by Bruce Miller;
GOOD SERVICE MANUAL GOT ALL THE INFO. THAT I NEEDED..

Text excerpt from page 3 (click to view)
INSTALLATION AND USER INSTRUCTIONS FOR COOKER HOOD TYPE "TL18GR" These instructions should be read carefully before the installation is done
Your new cooker hood can be used in the following ways:

Note � A damaged power supply cord must be changed by the Service because require a special tool.

Maintenance
N.B. Before any repairs, servicing or cleaning is carried out the plug must be disconnected. The grease filter should be washed every 10-15 days in hot water with detersive. It absorbs the particles of fat which become present during cooking and protects the kitchen and its furniture from deposits of grease. After successive washings however it should be replaced. The carbon filter functions during any type of cooking and is highly effective removing cooking smells and particles of grease which otherwise would be deposited on the walls and the furniture. Carbon filters cannot be washed. It is advisable to replace them every six months, depending on how frequently the hood is in use. In order to replace the filters mentioned above it is sufficient to open the grid of the cooker hood by pushing the fixing devices one towards the other pulling the grid outside until the control board is freed. The grease filter can be taken off by removing the retaining clips that hold it in its place, while the carbon filter can be freed by turning counter clockwise. The external parts of the cooker hood should be cleaned by using a damp sponge and liquid neutral detersive or a cloth dipped in neutralised alcohol. Please avoid cleaning products that contain scouring agents.

Extraction (exhaust mode)
In this case it is necessary to connect the hood to a tube (� 100�125 mm.) by using the connection piece which is supplied. The extracted air is then expelled to the outside.

Recirculation (filtering mode)
The air is purified by means of an active carbon filter (odour filter - Fig.2/C) and then returned into the room.

Summer/Winter use
To avoid loss of heat in winter it is advisable to use the hood as a recirculation hood. Warm air is purified and then redistributed into the room. Cooker hoods which are installed as extraction hoods are easily changed to recirculation hoods and vice-versa.

Installation
The cooker hood must be fixed directly under a kitchen unit, furthermore it must be installed centrally above the cooking hob. The minimum distance between the hob and the lower part of the cooker hood must be 650 mm. N.B. The above distance is subject to regulations in force for security in the respective countries. Extraction Hood When used in the extraction mode following points should be considered: The exhausted air should not be conducted in a chimney with warm air circulation. Do not connect the appliance to fuel exhaust flues or ventilating ducts. With venting into exhaust flues or ventilating ducts wich are no longer in use, it is advisable to obtain the approval of the responsible agency for the building. In the extraction mode the air is exhausted and conveyed through the ventilating duct upwards or directly to the outside. Attention: The shorter the exhaust duct is and the fewer bends there are in it, the more effective will the cooker hood be. Recirculation Hood When the hood is used in the recirculation mode and fitted with a carbon filter there is no need to connect the device (connection piece) to the tube. Installation under a Kitchen Unit N.B. Check that the unit is able to support the weight of the cooker hood. Turn the unit upside-down. Mark the holes for the screws. Corresponding to the air-outlet a hole for the connection piece of � 104/140 mm must be provided on the kitchen unit (for spigot of � 100/125 mm). Drill the holes for fixing the hood with a � 5 mm drill-bit. Lean the unit against the top part of the cooker hood and tighten it up to the hood with the 4 self-threading screws.

Security regulations
Cooking «en flambe» under the cooker hood is forbidden. When frying, constant watch must be given to all aspects of the ope-ration in particular because oil heated to a high temperature becomes inflammable easily. Frequent cleaning, in particular of the fan and the surfaces of the cooker hood, will avoid the risk of fire. The cleaning can be done with a cloth or small brush dipped in ethyl alcohol. Furthermore it is important to replace frequently each of the filters fitted in the cooker hood.

Suggestions for the use in extraction mode (exhaust version)
When the cooker hood is used in the extraction mode it is advisable to give particular attention to appliances and sources of heating at the same time in use (e.g. gas and oil heaters, coal or coke fires etc.) because the cooker hood sucks in the air which is needed for combustion by the above mentioned appliances causing a depression. During simultaneous use of heating appliances and cooker hood a max. depression of 0,04 mbar is advisable. In these conditions the risk of drawing in gases from heating appliances is avoided. This can be obtained by openings which cannot be closed e.g. in doors and windows or by other technical means. From these openings sufficient fresh air for combustion should be able to enter. Attention: To assess the situation fully all flues and vents in the apartment should be taken into consideration. If there is any doubt then it is advisable to obtain the approval of the responsible agency for the building. These precautions are not required when the cooker hood is used in the filtering version with carbon filter fitted.

Connecting to mains supply
Check that the mains supply is the same as that on the technical data plate which is attached to the cooker hood. Attention: If the appliance has no plug an allpole separation must be provided in the separation of the net with a minimum contact width of 3 mm each pole.

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

MECABLITZ 60 CT4 METZ
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 1.096 - Number of Queries: 125 - Query Time: 0.638